Development of Loop-Mediated Isothermal Amplification with a Lateral Flow Dipstick for Detection of the BlaOXA-23-like Gene from Carbapenem-Resistant Acinetobacter baumannii.
Saranthum Phurijaruyangkun, Pongbun Tangjitrungrot, Kantima Choosang, Adun Bunchaleamchai, Naiyana Wattanakul, Bajaree Jantrapanukorn, Rungnapa Veeramano, Suphitcha Augkarawaritsawong,
Faculty of Medical Technology, Rangsit University, Pathum Thani 12000, Thailand. · Center of Excellence in Biosensors, Panyananthaphikkhu Chonprathan Medical Center, Srinakharinwirot University, Nonthaburi 11120, Thailand.
Key points
From the paper's conclusion- This study aims to develop a lateral flow dipstick (LFD) assay that detects loop-mediated isothermal amplification (LAMP) products targeting the blaOXA-23-like gene, providing results within 1-1.5 h.
Abstract
Carbapenem-resistant Acinetobacter baumannii (CRAB) is a major cause of hospital-acquired infections. Conventional phenotyping for carbapenem resistance requires more than 24 h, which delays clinical decisions and increases the risk of outbreaks. This study aims to develop a lateral flow dipstick (LFD) assay that detects loop-mediated isothermal amplification (LAMP) products targeting the blaOXA-23-like gene, providing results within 1-1.5 h. Primer specificity was evaluated using seven Gram-positive and nine Gram-negative species commonly present in clinical samples, as well as carbapenem-susceptible A. baumannii and CRAB isolates harboring other resistance genes. The assay detected the blaOXA-23-like gene at concentrations as low as 1.57 pg/µL, demonstrating ~10-fold greater sensitivity than conventional PCR. The gene was present in 224/268 CRAB samples (83.6%) and absent in 100 carbapenem-susceptible A. baumannii samples. Results were fully concordant with PCR, yielding 100% sensitivity and specificity. The method requires no expensive or complex instrumentation. Future studies should validate the assay across multiple hospitals and clinical specimens to confirm its generalizability and clinical utility. Multiplex LAMP with dual LFD readouts could also enable simultaneous detection of additional carbapenem resistance genes, supporting rapid CRAB surveillance and outbreak control.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Direct Lateral Flow Detection of Carbapenemase-producing Acinetobacter baumannii From Screening Samples Using the RESIST ACINETO Lateral Flow Assay: A Proof-of-Concept Study.The Journal of hospital infection · 2026
- Multiplex RPA-CRISPR/Cas12a Assay for Rapid Detection of Class D OXA-Type Carbapenem-Resistant Acinetobacter baumannii.Biosensors · 2026
- Validation of NG-TEST Acineto-5 for the Detection of OXA Carbapenemases, NDM, and VIM in the Acinetobacter calcoaceticus-baumannii Complex and beyondmedRxiv · 2026
- Rapid visual and direct detection of Acinetobacter baumannii and carbapenem resistance by oligoDNA-gold nanoparticles biosensor in clinical samples.Diagnostic microbiology and infectious disease · 2026
- Recent Advances and Future Perspectives in the Detection of Carbapenem-Resistant Acinetobacter Baumannii.Infection and drug resistance · 2026
- Diagnostic accuracy of the RESIST-5 O.K.N.V.I. immunochromatographic assay for detection of carbapenemase-producing Gram-negative bacteria: comparison with real-time PCR.Diagnostic microbiology and infectious disease · 2026