The Hydraulic Response of a Roadside Drainage System to Urban Trail Encroachment: Integrated HEC-RAS, Culvert, and Erosion-Stability Assessment
Ahmad J. Alzubaidi, Haneen H. Darwish, Mutaz M. Zoubi, Mohammed N. Assaf, Trung Do, Nidal M. Hussein
Key points
From the paper's conclusion- Interpretation remains conditional because the higher-return-period StreamStats flows are extrapolated, field calibration data are unavailable, the stair-like energy-dissipation structure is not explicitly represented, and the terminal box culvert may influence the downstream-most hydraulic response.
Abstract
Urban trail construction can constrain existing roadside drainage corridors and alter water levels, flow velocity, culvert interaction, and erosion demand. This study evaluates a trail-constrained drainage retrofit in Moline, Illinois, USA, by linking changes in channel hydraulics to a proposed culvert-extension check and local lining demand. The study used StreamStats design hydrology, one-dimensional steady-flow HEC-RAS 6.5 outputs, HY-8 8.0.0 results, and HEC-15/IDOT riprap calculations. Existing and proposed conditions were compared at 24 matched HEC-RAS sections for the 10-, 25-, 50-, and 100-year events. Mean channel velocity decreased by 34.9–44.7%, while the median station-level water-surface-elevation (WSE) increase was 0.11–0.15 m; the corresponding mean WSE increase was 0.37–0.45 m because a small number of sections exhibited larger local changes. Velocity reductions were concentrated primarily within the reconstructed reaches, where mean reductions were about 54–56%; changes outside the reconstructed reaches were smaller and more variable. A targeted influence check excluding the anomalous downstream Station 2 found lower proposed-condition velocities at all 23 retained sections. A section-scale numerical sensitivity screening using plausible perturbations in roughness, discharge, and friction slope produced individual depth changes of less than 0.08 m at two representative reconstructed sections; a combined high-stage case increased depth by approximately 0.10–0.15 m without reversing the principal velocity-reduction pattern. The HY-8 calculation indicates that the proposed extension, 1.52 m in diameter, did not introduce an additional modeled restriction at the 100-year upstream design discharge of 5.89 m3/s, while the 10-year HEC-15 check showed that the lining satisfied the adopted stability criterion at all 13 evaluated design stations. Interpretation remains conditional because the higher-return-period StreamStats flows are extrapolated, field calibration data are unavailable, the stair-like energy-dissipation structure is not explicitly represented, and the terminal box culvert may influence the downstream-most hydraulic response. The case study therefore provides a conditional engineering comparison of channel, culvert-extension, and erosion-protection responses rather than a field-validated prediction of retrofit performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Criteria Hydraulic Design of Roadside DitchesDesigns · 2026
- Complete Network Assessment of Road Disruption and Heuristic Pipe Sizing in a Mountainous Transport HubWater · 2026
- Trail erosion assessment and monitoring in natural areas: a comparison of traditional and high-resolution topographic surveying methodsEnvironmental Monitoring and Assessment · 2026
- Urban Runoff Simulation Using HEC-RAS and the Modified Rational MethodWater Resources Management · 2026
- Reservoir-Release and Dam-Breach Flood Hazard to Highway Infrastructure in Central Vietnam: Integrated HEC-HMS and HEC-RAS Modeling and LULC Exposure AssessmentWater · 2026
- Paved Roads as Ecohydrological Modifiers: Slope-Driven Runoff Is Associated With Roadside Establishment of the Atlantic Halophyte Cochlearia danica in Continental Europe.Ecology and evolution · 2026