From the paper's conclusion- These results demonstrate that the combined effects of roof form, glazing orientation, glazed-to-opaque distribution, and resulting solar exposure govern thermal performance and sensitivity to future warming.
Abstract
Covering courtyards is a strategy for adapting heritage buildings to new uses, but its environmental effectiveness depends on the overall roof configuration and may be compromised by future warming. This study evaluates three translucent roof typologies—a sawtooth roof with south-facing vertical glazing (SAW), a semi-dome (SD), and a flat glazed roof (FLAT)—for a historic courtyard in Burgos, Spain. Performance was assessed through incident solar radiation, free-running indoor thermal behaviour, and annual heating and sensible cooling demands. The analysis comprised 27 simulations combining the three typologies with the current climate and four Shared Socioeconomic Pathways for 2050 and 2080. All eight future weather files were generated by morphing a single baseline TMY using ensemble-mean climate-change signals; consequently, inter-model dispersion and alternative downscaling or weather-generation methods were not assessed. Warming consistently reduced heating demand and increased sensible cooling demand, although the annual response differed among typologies. SAW achieved the lowest combined demand under all conditions, decreasing from 204.41 kWh/m2·year under the current climate to 153.53 kWh/m2·year under SSP5-8.5 in 2080. Over the same range, combined demand decreased from 261.37 to 235.49 kWh/m2·year for SD but increased from 224.61 to 238.02 kWh/m2·year for FLAT, as rising cooling requirements outweighed heating reductions. These results demonstrate that the combined effects of roof form, glazing orientation, glazed-to-opaque distribution, and resulting solar exposure govern thermal performance and sensitivity to future warming. Within the analysed decision set and weather-generation framework, SAW achieved the lowest combined thermal demand under all nine climatic conditions and was therefore identified as the minimax-regret alternative. This preference is limited to the thermal-energy criteria evaluated; conservation compatibility, reversibility, structural feasibility, fire safety, watertightness, maintenance, and visual compatibility with heritage values were outside the scope of the study. These findings are specific to the modelled building and should not be extrapolated to other courtyard geometries, orientations, construction systems, or climatic contexts without further case-specific analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative energy assessment of three glazed courtyard roof designs in a cold climate heritage buildingSustainable Energy Technologies and Assessments · 2026
- Climate change impact on envelope retrofit effectiveness: energy and carbon performance of Italian residential and office buildings today vs. 2050Energy and Buildings · 2026
- Balancing thermal comfort, construction feasibility, carbon emissions, and cost: multi-criteria evaluation of passive retrofits for high-rise social housingEnergy and Buildings · 2026
- Keeping Roofs Cool: A Key Strategy for Improving Thermal Comfort in Homes Across Three Climates of Burkina FasoBuildings · 2026
- Simulation of subtropical courtyard microclimate evolution and optimization algorithm for landscape design based on multi-source remote sensing data fusionScientific Reports · 2026
- Integrating Skycourts into Multi-Story Buildings for Enhancing Environmental Performance: A Case Study of a Residential Building in a Hot-Humid ClimateSustainability · 2025