Preoperative Injection of Indocyanine Green Fluorescence at the Anorectal Junction Safely Identifies the Inferior Mesenteric Artery in a Prospective Case-Series Analysis of Colorectal Cancer Patients
Franco Roviello, Eleonora Andreucci, Ludovico Carbone, Natale Calomino, Stefania Piccioni, Lucia Bobbio, Riccardo Piagnerelli, Andrea Fontani,
University of Siena · Azienda Ospedaliera Universitaria Senese
Key points
From the paper's conclusion- We assess the feasibility of ICG injection at the anorectal junction immediately before surgery to safely identify the inferior mesenteric artery (IMA).
Abstract
Background: Indocyanine green (ICG)-guided surgery is an emerging technique to enhance intraoperative visualization of nodes and tumor location. However, there is no uniform protocol regarding the optimal timing, dosage, or injection site for ICG in colorectal cancer surgery. We assess the feasibility of ICG injection at the anorectal junction immediately before surgery to safely identify the inferior mesenteric artery (IMA). Methods: This was a prospective study involving robotic left hemicolectomy or anterior resection of the rectum for primary colorectal cancer in 2024 in a single center. A total of 10–20 mg was injected into the anorectal submucosa at four quadrants circumferentially using an anoscope immediately before robot docking. Results: In this first study, ICG allowed us to identify the IMA in 84.6% of 26 patients (mean age 66.5 years; BMI 26.7 kg/m2), without intraoperative medical and surgical complications. Elevated BMI correlated with failure of IMA detection (r = −0.77, p < 0.001), despite high ICG doses trending toward improved vascular visualization (p = 0.097). A mean of 22 lymph nodes was harvested after ICG injection, with yields unaffected by the quality of IMA visualization. Conclusions: Submucosal injection of ICG is a feasible and easily adoptable option for early identification of the IMA, thereby preventing major vascular injuries, particularly in patients with challenging anatomy. A standardized protocol was implemented to improve reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Indocyanine Green Fluorescence Angiography in Colorectal Cancer Surgery After a Decade of Randomized Trials: From Visual Assessment to Quantification and Beyond.Cancers · 2026
- Use of Indocyanine Green Fluorescence in the Assessment of Bowel Perfusion in Emergency and Elective Colorectal Surgery: A Retrospective Cohort Study.Cureus · 2026
- Patient's weight-based indocyanine green dose for fluorescence angiography with led imaging system in left-sided colorectal resections.Surgical endoscopy · 2026
- Decreased fluorescence latency and plateau intensity ratio as predictive markers of intraoperative hypoperfusion: quantitative indocyanine green perfusion analysis in colorectal cancer surgeryAnnals of Coloproctology · 2026
- Prospective evaluation of indocyanine green fluorescence for anastomotic site selection in laparoscopic colorectal cancer surgery.Clinics (Sao Paulo, Brazil) · 2026
- The Role of Intraoperative Indocyanine Green Fluorescence Angiography in Reducing Anastomotic Leak After Colorectal Resection: A Systematic Review of Randomised Controlled Trials.Cureus · 2026