CFD-Based and Experimental Investigation of Indoor Air Quality: Particulate Matter Dispersion and Exposure in Library Buildings
Ali Ufuk Dibiç, Ahmet Çoşgun, Leyla Akbulut
Key points
From the paper's conclusion- The findings demonstrate that fine particles (PM0.3–PM1.0) remain suspended at occupant breathing height for extended durations, whereas coarse particles (PM5–PM10) predominantly undergo gravitational settling and accumulate near floor regions.
Abstract
Indoor air quality (IAQ) is a critical determinant of occupant health, comfort, and cognitive performance, particularly in densely occupied indoor environments such as libraries. This study aims to quantify particulate matter (PM) dispersion dynamics and exposure characteristics through an integrated experimental and computational framework. Three-dimensional CFD simulations were conducted using Flow-3D to resolve the transient transport behavior of multiple PM fractions (PM0.3–PM10) under realistic indoor conditions, and the numerical results were compared with in situ measurements obtained from two library buildings. The findings demonstrate that fine particles (PM0.3–PM1.0) remain suspended at occupant breathing height for extended durations, whereas coarse particles (PM5–PM10) predominantly undergo gravitational settling and accumulate near floor regions. Comparison of the numerical predictions with the experimental measurements showed closer correspondence for PM2.5 and PM10 than for the ultrafine particle fractions. However, because quantitative error metrics such as RMSE, MAPE, or R2 were not calculated in the present study, the level of predictive agreement is not expressed quantitatively. Larger discrepancies for ultrafine particles may be associated with their greater sensitivity to turbulent fluctuations and Brownian motion. Furthermore, the results highlight the critical role of airflow distribution, ventilation configuration, and spatial obstructions in governing particle transport and the formation of localized high-concentration zones. These findings underscore that ventilation effectiveness is primarily controlled by airflow patterns rather than airflow rate alone. The study indicates that CFD, when supported by experimental measurements, can provide a useful tool for assessing IAQ and informing ventilation design strategies to mitigate occupant exposure in indoor environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimentally Validated Discrete Phase Model for PM2.5 and PM10 with Numerical Transport MappingFluids · 2026
- Experimental and Numerical Insights into Indoor Contaminant Transport and Ventilation Performance: A ReviewEng · 2026
- Multi-Scale Computational Fluid Dynamics Investigation of Ventilation-Controlled and Gravity-Controlled Respiratory Aerosol Transport in an Office Environment: Implications for Heating, Ventilation, and Air Conditioning Design and Airborne Infection MitigationBuildings · 2026
- Assessment of personal exposure and spatial concentration variability in a small-scale chemical laboratory.Annals of work exposures and health · 2026
- Spatial Intelligence for Indoor Air Quality: Integrating Spatial Uncertainty Into Monitoring, Exposure Assessment, and Ventilation ControlIndoor Air · 2026
- Contextual Factors That Impact the Performance of Portable Air Cleaners: A Critical ReviewEnvironmental Science & Technology · 2026