Handheld Near-Infrared Spectroscopy Integrated with Pattern Recognition for Non-Destructive Discrimination of Rice Infected by an Aflatoxigenic Versus a Non-Aflatoxigenic Aspergillus flavus Isolate.
Zulipikaer Rouzi, Siyu Yao, Tong Yu, Ru Yan, Jin Wang, Xiyu He, Zuoyi Zhang, Luis E Rodriguez-Saona
Key Laboratory of Environmental Medicine and Engineering, Ministry of Education, and Department of Nutrition and Food Hygiene, School of Public Health, Southeast University, Nanjing 210009, China. · Nanjing Institute of Metrological Supervision and Testing, Nanjing 210009, China.
Key points
From the paper's conclusion- This study aimed to establish a rapid, non-destructive method for discriminating between aflatoxigenic and non-aflatoxigenic A. flavus infection and for the exploratory classification of AFB1 contamination levels in rice by integrating a handheld near-infrared (NIR) sensor with pattern recognition analysis.
Abstract
Aflatoxin B1 (AFB1), a highly carcinogenic metabolite produced by aflatoxigenic Aspergillus flavus, poses a serious threat to rice safety and public health. This study aimed to establish a rapid, non-destructive method for discriminating between aflatoxigenic and non-aflatoxigenic A. flavus infection and for the exploratory classification of AFB1 contamination levels in rice by integrating a handheld near-infrared (NIR) sensor with pattern recognition analysis. A total of 154 post-harvest rice samples were inoculated with aflatoxigenic A. flavus or non-aflatoxigenic A. flavus, or left untreated as controls. Spectra were collected from each sample, and pattern recognition analysis (PCA, SIMCA, OPLS-DA) was used to discriminate between infection types and to categorize AFB1 content. The uHPLC-MS/MS reference method quantified AFB1 concentrations ranging from 2.70 to 23.59 ppb at early infection stages. PCA revealed distinct separation trends among the three sample groups. The SIMCA model achieved 100.00% accuracy, sensitivity, and specificity for discriminating among the three infection types in internal validation, and hold-out validation on an independent sample set demonstrated effective discrimination, yielding 96.67% overall accuracy. OPLS-DA produced comparable results, with accuracies of 95.90% in internal validation and 96.67% in hold-out validation. Notably, the SIMCA model was also applied in an exploratory manner to classify AFB1 content into low-AFB1 (<4.0 ppb) and high-AFB1 (≥4.0 ppb) groups; under Monte Carlo cross-validation and hold-out validation, this grading model yielded a mean accuracy of 63.10% and 87.50%, which demonstrated the potential feasibility of AFB1-level grading by handheld NIR spectroscopy. This approach shows potential for rapid laboratory-based screening in food supply chains to support timely risk assessment and intervention to protect food safety and public health.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deciphering cross-scale spatiotemporal mapping and metabolic signatures of aflatoxins accumulation in Aspergillus-infected peanuts.Journal of hazardous materials · 2026
- Classification of Contaminated Dried Figs According to Their Aflatoxin B1 Concentrations by Deep Learning-Based VGG16 Model.Toxins · 2026
- Identification of Cadmium Contamination in Rice Using Near-Infrared Reflectance Spectroscopy and Machine Learning.Foods (Basel, Switzerland) · 2026
- Squeeze-Excitation Attention-Guided 3D Inception ResNet for Aflatoxin B1 Classification in Almonds Using Hyperspectral ImagingToxins · 2026
- Mold Detection in Sweet Tamarind During Storage Performed by Near-Infrared Spectroscopy and ChemometricsHorticulturae · 2026
- A Proof-of-Concept Study of Near-Infrared Spectroscopy and DD-SIMCA for Candida auris Strain AuthenticationSpectroscopy Journal · 2026