From the paper's conclusion
  • We evaluated a same-shift, enrichment-free workflow that couples the Pathotrak concentrator with real-time PCR (Bio-Rad iQ-Check Salmonella II) for quantifying Salmonella in raw poultry, with sample preparation in about 30 min instead of 6-24 h of enrichment.

Abstract

Salmonella in raw poultry drives foodborne outbreaks and recalls, and process-control decisions increasingly turn on quantitative thresholds rather than presence/absence. Acting on a threshold in real time requires accurate quantification near the cutoff and a result within one work shift. Conventional enrichment-based enumeration meets neither: it adds hours of growth before detection, and the growth step biases the count toward faster-growing, unstressed cells. Near-threshold false positives also matter: products below the limit tests positive, triggering costly and avoidable holds and recalls. We evaluated a same-shift, enrichment-free workflow that couples the Pathotrak concentrator with real-time PCR (Bio-Rad iQ-Check Salmonella II) for quantifying Salmonella in raw poultry, with sample preparation in about 30 min instead of 6-24 h of enrichment. The evaluation spanned 313 independent inoculations across three laboratories, three calendar years (2023-2025), and multiple seasons, technicians, instruments, and chicken sources. A latent-truth framework propagated inoculation uncertainty into sensitivity (Se) and specificity (Sp) estimates and made the half-log gray zone around each cutoff tractable. At 10 CFU/g, the workflow achieved Se 100% (20/20; 95% CI 83.2-100.0%) for samples at least 0.5 log10 above the threshold and Sp 94.4% (185/196; 95% CI 90.2-97.2%) below it; within the half-log gray zone, classification was Se 88.6% (95% CI 68.8-99.1%)/Sp 76.5% (95% CI 62.1-88.1%) (n = 77). In a cross-study comparison, gray-zone performance at 10 CFU/g fell within the range reported for MPN, with inoculation strain, chicken source, and plate-count method differing by site. At 1 CFU/g, the workflow returned a calibrated quantitative result within a single shift, which, to our knowledge, no enrichment-free real-time-PCR workflow has previously achieved without an incubation step. Samples more than 0.5 log10 CFU/g above or below a threshold were classified correctly in 205/216 (94.9%) cases at 10 CFU/g and 109/117 (93.2%; 95% CI 87.0-97.0%) at 1 CFU/g, with classification uncertainty confined to the gray zone (Se 63.2% (95% CI 49.9-76.0%)/Sp 66.5% (95% CI 54.2-77.9%), n = 166) as expected at low copy number (Salmonella genome copies estimated by qPCR).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers