Effects of Flame-Retardant Treatment on the Fire Behavior of Upholstered Sofas in a Residential Building in Brazil
George Cajaty Barbosa Braga, Cristiano Corrêa, Joaquim Pereira Lisboa Neto
Key points
From the paper's conclusion- The FR-treated sofa substantially enhanced occupant survivability and increased the probability of fire suppression crews intervening during the incipient phase within standard NFPA 1710 response deployment timelines.
Abstract
Residential fires cause substantial fatalities worldwide, yet upholstered furniture in Brazil rarely incorporates flame retardants (FR). This study evaluated the fire performance of a standard FR-free Brazilian sofa and compared it with an FR-treated sofa from the United Kingdom via full-scale compartment tests. The masonry enclosure was instrumented with thermocouples, heat flux gauges, and a residential smoke alarm. For the FR-free sofa, the smoke alarm activated at 1 min 47 s; temperatures measured at a height of 1.5 m exceeded 513 °C within 7 min 12 s, with the total heat flux approaching 22 kW/m2 and the 100 °C tenability threshold reached at 2 min 34 s (leaving only 47 s for post-alarm egress). In contrast, the FR-treated sofa suppressed initial fire spread for over 10 min, delaying alarm activation to 4 min 01 s and the 100 °C threshold to 14 min 42 s, extending safe evacuation time to 10 min 41 s. Peak thermal conditions (373 °C; 12.2 kW/m2) were deferred beyond 24 min. The FR-treated sofa substantially enhanced occupant survivability and increased the probability of fire suppression crews intervening during the incipient phase within standard NFPA 1710 response deployment timelines.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- When the Cable Insulation Burns: Experimental and 2D Modeling Study of Cables with Flame-Retardant Sheaths and Flammable InsulationFire Technology · 2026
- Thermal runaway jet flames of lithium iron phosphate batteries under inclined ceilings: Flame dynamics, ceiling thermal exposure, and safety evaluationApplied Thermal Engineering · 2026
- Fabrication and Performance of Thermally Triggered Active Fire-Extinguishing Patches Based on Perfluorohexanone Microcapsule-Modified Epoxy Resin.Polymers · 2026
- Impact of metal corrosion on the process safety of foam fire suppression systemProcess Safety Progress · 2026
- Comprehensive Experimental Study on the Fire Hazards of LiPF6-Based ElectrolytesFire · 2026
- Dual‐Phase Flame‐Retardant Action of Bio‐Based DOPO ‐ ITA : Improved Fire Safety, Thermal Stability and Mechanical Properties of Rigid Polyurethane FoamJournal of Vinyl and Additive Technology · 2026