Smart Fitness Solutions: An Edge-Computing Approach for Biometric Monitoring and Real-Time Muscle Fatigue Detection
Mohamed Ahmed El Ghazouly, Duaa Zuhair Al-Hamid, Omar Gadelmawla, Hamid GholamHosseini, Mirza Mansoor Baig, Shereen Afifi
Key points
From the paper's conclusion- Real-time monitoring of muscle fatigue could support safer strength training, yet most wearable systems depend on cloud processing, which adds latency and exposes physiological data.
Abstract
Real-time monitoring of muscle fatigue could support safer strength training, yet most wearable systems depend on cloud processing, which adds latency and exposes physiological data. This work presents and evaluates an edge-based prototype for biometric monitoring during biceps curls. A wearable node integrating a nine-axis IMU (MPU-9250) and a photoplethysmography heart-rate sensor (MAX30102) streams data from an ESP32 microcontroller over UDP to a Raspberry Pi 5, which performs feature scaling and inference with a compact feedforward neural network (two hidden layers of 64 and 32 units) trained on a publicly available biceps-curl dataset. The classifier takes a 10-element feature vector of IMU, heart-rate and acceleration-derived inputs and outputs three fatigue levels. Under leave-one-subject-out cross-validation on ten participants, the three-class classifier attained a mean accuracy of 0.77 (SD 0.25; 95% CI 0.59–0.95), with a strongly bimodal per-subject distribution (0.40–0.98). Deployed on the edge node and evaluated end-to-end over 5172 annotated windows under a binary no fatigue versus fatigue formulation, the model recovered 91% of non-fatigued but only 10% of fatigued windows (balanced accuracy 0.51, Matthews correlation 0.02), which is no better than chance and below a majority-class baseline. In its current form the classifier is therefore not a reliable fatigue detector; we analyse candidate causes, including training-side class skew and differences between the source-dataset and deployment sensors, and compare them against majority-class and chance reference points. On the systems side, the pipeline runs fully locally with 10 ms model inference per sample, 42 ms gateway processing and a mean wireless round-trip time of 180 ms after rate-limiting the link. The implemented physical, communication and edge-inference layers are designed as the sensing foundation for a future Digital Twin, which is not implemented in this work.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-Time Physiological Fatigue Prediction for Human-Robot Collaborative Manufacturing Using Wearable Sensor Fusion and Hybrid Deep Learning: An In Silico Digital Twin Study.Sensors (Basel, Switzerland) · 2026
- Applying Deep Learning to Image and IMU Sensor Data for Real-Time Fatigue Recognition in Table Tennis Players.Sensors (Basel, Switzerland) · 2026
- Application of inertial measurement units and machine learning for fatigue assessment in badminton athletes.Frontiers in physiology · 2026
- AI-Enabled Wearable Sensor Technologies for Athlete Performance Monitoring: A Critical Review of Signal Processing, Machine Learning, and Real-Time Embedded Systems2026
- From Biosignals to Bedside: A Review of Real-Time Edge Machine Learning for Wearable Health MonitoringBioengineering · 2026
- Onset Forecasting of Hand-Arm Fatigue via Physics-Informed Machine Learning and Wearable IMU SensorsJournal of Physics: Conference Series · 2026