Eng

Explainable Deep Learning for Image-Based Critical Heat Flux and Fluid Flow Detection in Pool Boiling: A Multi-Architecture Benchmark with Mass Flow Rate Regression

Zainab Talib Al-Sharify, Firas M. Abdulsattar, Samer Ata Qasim Al-Ajooli, Ahmed Ali Farhan Ogaili, Alaa Abdulhady Jaber

Computational

Key points

From the paper's conclusion
  • An accuracy–efficiency analysis identifies DL-Optimum as accuracy-Pareto-optimal (26.30 M parameters; 332 FPS single-pass, ≈33 FPS under the full ten-pass test-time-augmentation protocol) and EfficientNet-B0 as efficiency-Pareto-optimal, and DL-Optimum achieves a 3.2 percentage-point higher in-distribution accuracy than the best published image-based CHF baseline (0.930) and a 1.2 percentage-point

Abstract

Early, non-invasive detection of the critical heat flux (CHF) is essential for the safe operation of nuclear, electronic-cooling and other high-heat-flux systems, yet conventional thermocouple-based monitoring is invasive, slow and point-wise. This paper presents an explainable deep-learning framework that classifies high-speed pool-boiling imagery into pre-CHF and post-CHF regimes and, in the same forward pass, regresses the energy-balance-derived equivalent vapour mass flux m″v. The proposed DL-Optimum model—a ResNet-50 backbone augmented with Squeeze-and-Excitation channel attention, label smoothing, cosine-annealed warm restarts and five-crop test-time augmentation—is benchmarked against six architectures on the open NED3 pool-boiling corpus of 3000 frames, and a stepwise ablation ladder (A0–A4) quantifies the cumulative contribution of each modification. DL-Optimum attains the highest performance (accuracy 0.9622, F1 0.9625, AUC-ROC 0.9772), reproduced under five-fold cross-validation (0.9622 ± 0.0058), confirmed on each of the five condition groups individually (0.939–0.983) and generalising to entirely unseen condition groups under leave-one-group-out cross-validation (0.8827 ± 0.0293). The regression head achieves an MAE of 0.041 kg·m−2·s−1 (R2 = 0.913) against the energy-balance ground truth. Grad-CAM attributions are consistent with physically relevant regions—nucleation-site activity and vapour-blanket morphology—Monte-Carlo Dropout yields calibrated confidence (predictive entropy 0.0674 ± 0.1024), and stress tests retain 0.902 accuracy from 10% of the training data and 0.938 at σ = 0.20 additive noise. An accuracy–efficiency analysis identifies DL-Optimum as accuracy-Pareto-optimal (26.30 M parameters; 332 FPS single-pass, ≈33 FPS under the full ten-pass test-time-augmentation protocol) and EfficientNet-B0 as efficiency-Pareto-optimal, and DL-Optimum achieves a 3.2 percentage-point higher in-distribution accuracy than the best published image-based CHF baseline (0.930) and a 1.2 percentage-point higher accuracy than the published acoustic baseline (0.950), though direct comparisons remain subject to cross-study differences in datasets and evaluation protocols.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Explainable Deep Learning for Image-Based Critical Heat Flux and Fluid Flow Detection in Pool Boiling: A Multi-Architecture Benchmark with Mass Flow Rate Regression — Science Skim