Parametric CFD Analysis of Annular Groove Geometry on Nucleation Dynamics and Thermal Resistance in Thermosyphon Heat Pipes
Shek Mohammod Atiqure Rahman, Salah Issa, Essam M. Abo Zahhad, Ahmed Amine Hachicha, Mamdouh El Haj Assad, Md Hasanuzzaman, Ali Mohammed Radwan
Key points
From the paper's conclusion- This study makes three contributions: it quantifies, from resolved vapor fields, the link between annular groove geometry and local vapor-generation behavior; it identifies the competing influence of groove-enhanced vapor generation against groove-induced vapor retention within a single computational framework; and it identifies the best of the tested groove spacing-to-width combinations.
Abstract
Annular grooves are widely proposed as a passive enhancement for two-phase closed thermosyphons, yet the literature reports their effect almost exclusively through global thermal metrics, leaving the underlying vapor-generation and vapor-retention mechanisms largely unquantified. This study makes three contributions: it quantifies, from resolved vapor fields, the link between annular groove geometry and local vapor-generation behavior; it identifies the competing influence of groove-enhanced vapor generation against groove-induced vapor retention within a single computational framework; and it identifies the best of the tested groove spacing-to-width combinations. A transient two-dimensional volume-of-fluid model, closed by a temperature-driven Lee-type user-defined function for evaporation and condensation, was developed for a water-charged copper thermosyphon at two heat inputs, 81 W and 101 W. The smooth-wall model was validated against published experimental wall temperatures with a mean deviation of 4.15% (maximum about 5.7% at the condenser end); the grooved cases were assessed through trend comparison with grooved and corrugated thermosyphon studies. Groove spacing was varied between 2.5, 5.0 and 10.0 mm (width 1.0 mm), and groove width between 0.5, 1.0 and 1.5 mm (spacing 5 mm). Grooves lowered the peak (hot-spot) wall temperature by 2.6 K at 81 W and 4.3 K at 101 W and raised the evaporator vapor fraction by about 12–19%; widening the grooves from 1.0 to 1.5 mm increased the number of active vapor sites by about 19%. Reducing the groove spacing promoted earlier and more frequent vapor release, whereas increasing the groove width raised vapor generation but prolonged vapor residence. The overall thermal resistance of the grooved pipe was slightly higher than that of the smooth pipe (by about 1.4% at 81 W and 2.2% at 101 W), so the local gains do not automatically give lower overall resistance. The best tested combination was S = 5 mm and W = 1.0 mm (S/W = 5); the thermal resistance of the five simulated groove combinations differed by only about 0.5%. The results provide comparative design guidance for grooved thermosyphons.:
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mathematical Modeling and Experimental Assessment of Heat Transfer in a Field-Tube Evaporator of a Closed-Loop Two-Phase ThermosyphonApplied Sciences · 2026
- Thermal Performance of an Aluminum-Ammonia Axially Grooved Heat Pipe with Bends and Discrete Heat SourcesEnergies · 2026
- Influence of groove orientation and number on pool boiling heat transfer of water: experimental analysis and ANN modelingInternational Journal of Thermofluids · 2026
- Comparative Study on Experiment and Numerical Simulation of Annular Multiphase FlowProcesses · 2026