Simulation-Based Resiliency Assessment of Hybrid Energy Systems: Application to a Sustainable Community in Africa
Hossam A. Gabbar, Zainab Lawal
Key points
From the paper's conclusion- The findings identify service shortfalls and limitations of backup support, providing a basis for comparing operating configurations and dispatch settings.
Abstract
Reliable delivery of electricity, freshwater, hydrogen, and cooling remains challenging in remote communities where these services share generation, conversion, and storage resources. This study develops a simulation-based framework for assessing resiliency of multi-service performance under prescribed disturbances in Gbamu-Gbamu, Nigeria. The proposed multigeneration system combines renewable and waste-to-energy/biogas resources with battery and hydrogen storage, fuel-cell support, desalination, and cooling. MG-OPT, implemented in Python 3.13.18 and executed in Google Colab, MATLAB R2026a Update 5 with Simulink 26.1 (R2026a), and HOMER Pro 3.18.3 (64-bit, Pro Edition) support configuration assessment, technology comparisons, disturbance simulations, and techno-economic analysis. Individual service-coverage indicators and an Integrated Service Performance Score (ISPS) quantify demand satisfaction. Critical-service thresholds are assessed separately, while an eight-state descriptive framework defines operating conditions and response phases. Conditional fault-tree screening, dependence sensitivity tests, and Monte Carlo parameter propagation examine the effects of assumed event probabilities and selected dependencies. Four operating configurations are simulated. The Maximum Cooling Coverage case is selected for detailed assessment of a compound disturbance from 4.001 to 8.001 h. Its mean disturbance-period ISPS is 0.3188, and the Disturbance-Period Performance Preservation Index (DPPI) is 0.5249. Battery discharge and fuel-cell generation supply 232.75 and 31.81 kWh, respectively, over the 12 h simulation. However, aggregate village electricity supply remains below the 2.0833 kW critical-load proxy for 1.6443 h. Numerical checks support consistency with the implemented power balances, storage balances, and operating bounds. The assessment quantifies service degradation and its duration under prescribed availability signals without predicting physically calibrated equipment recovery. The findings identify service shortfalls and limitations of backup support, providing a basis for comparing operating configurations and dispatch settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrated Simulation and Resiliency Assessment of Hybrid Energy SystemsSmart Cities · 2026
- Reliability-conscious power flow optimization in hybrid renewable microgrids: a case study in Sub-Saharan Africa using Gauss-Seidel and metaheuristic techniquesInternational Journal of Electrical Power & Energy Systems · 2025
- Analysis of a Sustainable Hybrid Microgrid Based on Solar Energy, Biomass, and Storage for Rural Electrification in Isolated CommunitiesApplied Sciences · 2025
- Optimal design of hybrid renewable energy conversion systems using two configurations and four different algorithms for a rural village in EgyptDiscover Applied Sciences · 2026
- Energy Storage for Off-Grid Communities: A Structured Global Inventory of 2348 Real Sites, Multi-Criteria Comparison, and Site-Specific RecommendationsEnergies · 2026
- Sustainable energy solutions for rural Bangladesh: an optimized hybrid microgrid modelFrontiers in Energy Research · 2025