Evaluating Thermostat Demand Response Under Limited Telemetry: Window Sensitivity and Conclusion Stability
Mingzhi Yang, Yue Liu, Lei Zhang
Key points
From the paper's conclusion- The findings support explicit reporting of window definitions and conclusion stability, without validating household targeting, override attribution, or measured energy savings.
Abstract
Demand-response (DR) evaluation depends on the observation window, but thermostat labels may not identify complete dispatch boundaries. We examined how active-label and fixed-duration windows affect cooling-runtime response estimates, uncertainty-qualified categories, and descriptive household comparisons in cleaned 2017 ecobee data. Three past-only baselines were evaluated using a forward calendar split. Among 175 common September onsets from 59 homes, the matched mean response was 62.72 s per five-minute step lower in the four-hour than in the active-label window (approximate household-by-date 95% interval for the difference: [−99.57,−29.29]). Across models, 30.3–45.1% of onsets changed category, predominantly becoming unresolved rather than reversing a resolved sign. Upper-quarter household membership also changed across windows, including in a balanced repeat-home analysis. Non-DR references and split-half checks qualify these exploratory comparisons. Uncertain dispatch ends and zero-fill ambiguity preclude causal interpretation. The findings support explicit reporting of window definitions and conclusion stability, without validating household targeting, override attribution, or measured energy savings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Counterfactual Probabilistic Electricity Load Baseline Estimation for Demand Response Using Contemporaneous Non-Activated CustomersEnergies · 2026
- NILM-Based Feedback for Demand Response: A Reproducible Binary State-Detection Algorithm Using Active PowerElectricity · 2026
- From Day-Ahead Grid Signals to Household Action: Communicating Variable Grid Tariffs in an Austrian Regulatory SandboxACM SIGEnergy Energy Informatics Review · 2026
- Quantifying the impact of occupancy sensor errors on energy savings, thermal comfort, and peak demand in residential smart thermostatsJournal of Building Performance Simulation · 2026
- Towards Explainable and Resilience-Oriented Electricity-Demand Forecasting: A Structured Retrospective Narrative Systematic Review and Integrated Framework for AI-Enabled Energy GovernanceSustainability · 2026
- Adaptive RF–ARX Ensemble Forecasting of Next-Day PUE with Limited Daily DataEnergies · 2026