Daily and monthly balances ignore the hourly simultaneity of photovoltaic (PV) output and heat pump consumption. Hourly output of four PV systems was combined with the measured consumption of an air-source heat pump in a single house near Wrocław, Poland, about 15 km from the reference system, whose capacity was scaled to 2–15 kWp. Annual values are sums over 316 days of one year (2025–2026) with complete data. At the actual capacity (6.12 kWp), the self-consumption by the heat pump is 13.3% and its self-sufficiency 11.6%, both upper estimates. The coupled energy (PV output used by the heat pump in the same hour) increases by 96 kWh per added kWp at 2–3 kWp and 25 kWh at 12–15 kWp. Daily sums give 3.2–3.4 times and monthly sums 3.7 times as much coupled energy as the hourly balance. Daily PV sums from a system 4 km from the house change the coupled energy by 2.1%. A single-parameter correction φ(r) of daily balances gives an annual error of 3.9–9.7% for the reference system and from −6.3% to 7.5% for the other three and suits annual, not monthly, balances. The results concern one heat pump with its operating schedule and one year.