Power System Zoning and Regional Minimum Inertia Requirement Assessment Based on an Improved Spectral Clustering Approach
Meng Zhu, Yang Liu, Di An, Xin Hui, Kexin Li, Mo Zhou, Yibo Zhou, Xiaotian Zhang,
Key points
From the paper's conclusion- The proposed method provides a reference for regional inertia assessment and frequency-security control in power systems with high renewable penetration.
Abstract
With the large-scale integration of renewable-energy generating units, power-system inertia continues to decline and becomes unevenly distributed in space. Consequently, frequency responses differ markedly among regions following a disturbance, and assessment based on a single center-of-inertia (COI) frequency may conceal local frequency-security risks. This paper proposes a regional inertia assessment and minimum-inertia calculation method based on linearized analysis. First, a generalized relative correlation gain matrix is constructed from a linearized multi-machine model to quantify the dynamic correlation of generator frequency responses. Spectral clustering and the Calinski–Harabasz (CH) index are then used to determine the system partition. Next, synchronous-machine inertia, load-voltage characteristics, virtual inertia, and primary frequency control are considered in stages. The minimum regional inertia requirements are calculated under rate-of-change-of-frequency (RoCoF) and frequency-nadir constraints, and the larger value is taken as the regional inertia threshold. Simulations on the IEEE 10-machine 39-bus system show that the proposed partitions capture regional differences in frequency response and that the estimated values agree closely with the actual aggregated inertia after synchronous machines are replaced. When inertia is configured according to the calculated thresholds, the RoCoF and frequency nadir in every region satisfy the security constraints. Further analysis shows that the minimum inertia requirements under both constraints increase with disturbance magnitude. At a stringent RoCoF limit, the requirement is dominated by the RoCoF constraint; as the limit is relaxed, the frequency-nadir constraint progressively becomes dominant. The proposed method provides a reference for regional inertia assessment and frequency-security control in power systems with high renewable penetration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating the minimum inertia of power systems with consideration for wind power in frequency regulationInternational Journal of Electrical Power & Energy Systems · 2026
- Review on Frequency Security Assessment and Coordinated Inertia Control for Low-Inertia Modern Power SystemsDOAJ (DOAJ: Directory of Open Access Journals) · 2026
- Inertia estimation for power grids: A review of methods, challenges, and future prospectsApplied Energy · 2026
- Inertia Estimation for Power Generation Units Based on Dual Neural Networks and a Polynomial Ridge Regression Fusion ModelSymmetry · 2026
- Nodal Inertia Pricing for RoCoF Security with Integration of Synchronous and Virtual ResourcesarXiv · 2026