An Experimental Study on the Effect of Electronic Expansion Valve Opening on the Performance of a Closed-Loop Transcritical CO2 Heat Pump Drying System
Yaxiang Hou, Zheming Cheng
Key points
From the paper's conclusion- The opening of an electronic expansion valve (EEV) directly affects the operating characteristics, heating capacity, and dehumidification performance of a closed-loop CO2 heat pump drying (HPD) system.
Abstract
The opening of an electronic expansion valve (EEV) directly affects the operating characteristics, heating capacity, and dehumidification performance of a closed-loop CO2 heat pump drying (HPD) system. To clarify the underlying mechanisms governing these effects, experiments were conducted on a closed-loop CO2 HPD test platform to examine the variations in system operating parameters and performance metrics under different EEV openings. With an increase in EEV opening from 20% to 50%, the heating and refrigeration capacities, together with the total power consumption, decreased continuously. In contrast, the heat exchange capacity of the internal heat exchanger increased progressively. The discharge pressures of the compressor and EEV inlet declined continuously, whereas the compressor suction pressure and EEV outlet pressure showed a gradual increase. Both the coefficient of performance (COP) and specific moisture extraction rate (SMER) increased initially and subsequently declined, whereas the moisture extraction rate (MER) decreased progressively. The SMER exhibited a maximum variation of 5.32% between its highest and lowest values.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A comparative conceptual analysis of CO2 heat pump dryers with closed-loop and open-loop air cyclesEnergy Conversion and Management · 2026
- Experimental study on the performance of a two-stage heat pump drying system coupled with rotary dehumidification and total heat recoveryCase Studies in Thermal Engineering · 2026
- Experimental evaluation of a R290 vapour compression refrigeration system hybridised with a thermoelectric subcoolerEnergy Conversion and Management · 2026
- Theoretical assessment of thermoelectric subcooling integration into a propane vertical freezing cabinet to minimize its energy consumptionEnergy · 2026
- Multi-Objective Evaluation of Recirculating Air-Conditioning Operation in University Dormitories: Thermal Comfort, CO2 Exposure, and Energy UseBuildings · 2026
- Physics-Guided Bioinspired Multi-Objective Optimization for Explainable Drying-Stage Identification in an R290/R600a Waste-Heat Drying System.Biomimetics (Basel, Switzerland) · 2026