Energy, Exergy, and Exergoeconomic Assessment of a Combined-Cycle Power Plant
Gustavo Basílio Lima, Júlia Alves Santos, Lucas Haas, Jocélio Jairo Vieira, José Vinícius Santos de Araújo, João Alves de Lima, Gilberto Augusto Amado Moreira, Ademar Virgolino da Silva da Silva Netto,
Key points
From the paper's conclusion- This study presents a Python-based thermodynamic model of an isolated natural gas-fired CCGT power plant, applied to 1027 steady-state operating points recorded over one month of operation.
Abstract
Combined-cycle gas turbine (CCGT) power plants play an important role in reducing greenhouse gas emissions while maintaining high thermal efficiency. Accurate thermodynamic models are essential for evaluating plant performance under different operating conditions and supporting improvements in energy resource management. This study presents a Python-based thermodynamic model of an isolated natural gas-fired CCGT power plant, applied to 1027 steady-state operating points recorded over one month of operation. The model integrates energy, exergy, and exergoeconomic analyses based on the Specific Exergy Costing (SPECO) methodology to assess plant operation with and without supplementary firing. The model was validated against the measured steam production, with a mean absolute percentage error of 2.8%. The proposed methodology enables the evaluation of component efficiencies, exergy destruction, cost formation, and the influence of different operating modes on electricity production. The plant achieved median gross first- and second-law efficiencies of 46.6% and 44.6%, respectively (45.1% and 43.2% on a net basis). The combustion chamber exhibited the highest exergy destruction in both operating modes, while the supplementary burner became one of the major sources of irreversibility when supplementary firing was activated. The specific exergy cost of electricity decreased from about 21.0 to 14.2 $/GJ as the electrical output increased from 11.3 to 20.9 MW, with a median of 16.47 $/GJ in the period. The supplementary burner presented the highest relative cost difference (median of 1.06), whereas the combustion chamber had the highest exergy destruction rate and cost rate of exergy destruction. The proposed model provides a flexible and reproducible framework for evaluating CCGT power plants and can support operational assessment and decision-making aimed at improving thermodynamic and economic performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Process Simulation and Validation of a Combined Cycle Gas Turbine Power Plant for Flexible Operation Under Energy Transition ChallengesEPJ Web of Conferences · 2026
- Performance assessment of an industrial F-class combined cycle power plant with an air-cooled condenser using energy and exergy analysisScientific Reports · 2026
- Exergoeconomic Analysis of a Gas Turbine Integrated with Supercritical CO2 Energy Storage and Cascade Heat Utilization Considering Different Operating PeriodsApplied Sciences · 2026
- Energy and Exergy Analysis of a Combined Cycle Power Plant with Ice Thermal Energy Storage-Based Inlet Air CoolingEnergies · 2026
- Exergoeconomic Analysis of Power Plants: Impact of Exergy Destruction Due to Entropy Generation on Unit Cost of Electricity.Entropy (Basel, Switzerland) · 2026
- Performance Improvement and Repowering Strategies for an Existing Sugarcane Cogeneration Plant: Energy, Exergy, Economic and Environmental AssessmentEnergies · 2026