Condition-Monitoring-Based Reliability and Profit Optimization of PEM Electrolyser: A Multi-State Semi-Markov Approach with Derated Operation and Logistics Delay
Syed Mohd Rizwan, Santosh Walke, Shabib Sulaiman Ali Al Rashdi
Key points
From the paper's conclusion- The results show that models omitting preventive maintenance and shock-type failures overstate electrolyser availability, with direct consequences for hydrogen supply planning and plant economics.
Abstract
Proton exchange membrane (PEM) water electrolysis is a key technology for converting renewable electricity into green hydrogen, and the availability of electrolyser stacks directly determines the hydrogen output and economics of such plants. This paper extends a previously reported ten-state semi-Markov reliability model of a PEM electrolyser into a twenty-state framework that better reflects field behaviour. The extension adds a derated, partial-output operating state for each of four degradation mechanisms (membrane, electrode, chemical and thermal), a spares-waiting state that separates logistics delay from active repair, a scheduled preventive-maintenance branch, and a rare catastrophic-shock branch, all treated as competing risks at the operative state. Closed-form steady-state expressions are derived for availability, mean time to system failure (MTSF) and maintenance-crew busy periods. A delta-method procedure converts sensitivity coefficients into a confidence interval on availability, and a profit function balances hydrogen revenue against inspection, derating, logistics and repair costs. Using plant rates from a pilot-scale electrolyser and literature-informed values for the new parameters, the model gives a steady-state availability of 0.8804 (95% CI: 0.778–0.983), a production-equivalent availability of 0.8856 that credits the output of derated states, an MTSF of about 5297 h and an illustrative net profit rate of $191.03/h after electricity cost. The results show that models omitting preventive maintenance and shock-type failures overstate electrolyser availability, with direct consequences for hydrogen supply planning and plant economics. Numerical Markov-chain solution and Monte Carlo simulation verify the closed-form results, and transient, sensitivity and operating-condition analyses identify membrane degradation as the mechanism whose maintenance matters most.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating hydrogen electrolyzer maintenance strategies using event-based modelingInternational Journal of Hydrogen Energy · 2026
- Degradation-Aware Lifecycle Efficiency Modeling and Extremum-Seeking Control of Proton Exchange Membrane Water ElectrolyzersEnergies · 2026
- Granularity-Aware Capacity Planning of Alkaline and PEM Electrolyzers Under Heterogeneous Operating StressProcesses · 2026
- A Systematic Benchmarking of PEM Electrolyser Degradation: Towards a standardised methodology for experimental degradation campaignsInternational Journal of Hydrogen Energy · 2026
- Comparative assessment of multiphysics modelling approaches of PEM electrolysers for real-time Digital Twin implementationJournal of Physics: Conference Series · 2026
- Fault tree and importance measure analysis of a PEM electrolyzer for hydrogen production at a nuclear power plantInternational Journal of Hydrogen Energy · 2025