Hydraulic Coupling Suppression Control Method for Complex Hydraulic Systems Based on Feedforward Synergetic Compensation of Guide Vane Opening
Yong Zhao, Fangfang Wang, Hongyue Zhen, Ke Zuo, Manguo Zhou, Yun Zeng
Key points
From the paper's conclusion- To address the control problem caused by the impact of hydraulic coupling on the output of complex hydraulic systems, this paper proposes a synergetic feedforward control method based on the rate of water level change in the surge tank.
Abstract
With the increasing scale of cross-basin hydraulic engineering and cascaded hydropower stations, hydraulic systems exhibit complex characteristics such as long-distance, nonlinear, and multivariable coupling. The dynamic interaction among hydraulic parameters can easily induce pressure oscillations and flow fluctuations, posing a serious challenge to the safe and stable operation of the system. To address the control problem caused by the impact of hydraulic coupling on the output of complex hydraulic systems, this paper proposes a synergetic feedforward control method based on the rate of water level change in the surge tank. This method uses the rate of water level variation as a real-time indicator of hydraulic coupling intensity and, through theoretical derivation, establishes an analytical relationship between the guide vane opening compensation and the rate of water level change for each unit. For complex topological configurations, the feedforward weight coefficients are separately derived for single penstock–single machine systems and single penstock–two machine systems. Theoretical analysis shows that the proposed method automatically resets to zero under steady-state conditions, fundamentally eliminating the issue of steady-state opening deviation. It also exhibits phase-leading characteristics, enabling it to act in advance during the early stage of a disturbance. In addition, filtering is applied to suppress wave spikes that occur under certain parameter settings. Simulink simulations have verified the effectiveness of this method in mitigating hydraulic coupling, and the influence of key parameters on control performance has also been analyzed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi‐Time Scale Hydraulic‐Mechanical‐Electrical Coupling Transient Response of Three‐Stage Cascaded Hydropower Stations With Surge TanksEnergy Science & Engineering · 2026
- Hydraulic Performance of Energy-Dissipation Configurations for a High-Dam Fish-Lift Collection System: A CFD-Based Comparative StudyWater · 2026
- Research on the Adaptation Mechanism of Structural Parameters and Shock Suppression for Shift Buffer Valves Based on Multi-scale Characteristic FusionJournal of Physics: Conference Series · 2026
- Full-3D Compressible Pressure Pulsations Analysis of a Huge Francis-Type Pump-Turbine Unit Coupled with Its Water Conveyance System: Modeling Implications for Flexible Hydropower OperationMachines · 2026
- Extreme water hammer pressure of spiral case in hydropower station with super long headrace tunnel and surge tank during load rejection: Mechanism analysis and improvement measuresPhysics of Fluids · 2025
- Improving the assessment of the head losses in the penstock of a hydroelectric damFrontiers in Environmental Engineering · 2026