Energies

System-Level Assessment Methodology for PV–AEL–H2–PEMFC Power-to-Power Systems: Constant-Efficiency Versus Quasi-Dynamic Modeling

Andrés Villarruel-Jaramillo, Freddy Nieto, Ignacio Arias, José M. Cardemil, Kenny Escobar-Segovia, Edgar Cando, Salvatore Reina

Computational

Key points

From the paper's conclusion
  • Overall, operating-point-dependent models materially alter annual PTP performance estimates under variable renewable operation.

Abstract

Hydrogen-based power-to-power (PTP) systems complement batteries for long-duration storage, but their assessment often assumes fixed electrolyzer and fuel-cell efficiencies. The main innovation of this work is developing a system-level methodology to quantify how component-model fidelity affects the annual assessment of photovoltaic-alkaline electrolyzer-hydrogen-proton exchange membrane fuel cell systems. To highlight parameter and operational differences, two approaches are compared for the Santa Cruz–Baltra case study. Case A relies on simplified parameter assumptions, using fixed AEL and PEMFC efficiencies of 0.65 and 0.52. In contrast, Case B resolves operational differences by capturing operating-point-dependent electrochemical behavior, part-load variations, and AEL thermal-state propagation. Both cases use identical system boundaries and supervisory control, allowing model-fidelity effects on hydrogen production, storage utilization, and electricity recovery to be quantified. Annual simulations show that Case A predicts higher recovered electricity than Case B. For a representative configuration, global efficiency decreases from 0.529 to 0.440 (a 17% relative difference). The largest relative difference in recovered electricity (~91%) occurs in constrained configurations. Component-level experimental validation does not constitute full system-level validation. Overall, operating-point-dependent models materially alter annual PTP performance estimates under variable renewable operation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

System-Level Assessment Methodology for PV–AEL–H2–PEMFC Power-to-Power Systems: Constant-Efficiency Versus Quasi-Dynamic Modeling — Science Skim