Research and Performance Verification of a Flexible Interconnection Architecture for Distribution Networks Based on a Hybrid Series–Parallel Structure
Ping Lou, Xiaozhong Wang, Xiang Yan, Lei Zhang, Min Yan, Penghui Shang
Key points
From the paper's conclusion- To address these issues, this paper proposes a flexible AC controllable interconnection device based on a hybrid series–parallel structure.
Abstract
The “closed-loop design, open-loop operation” scheme traditionally adopted by distribution networks results in limited power-flow regulation capability and insufficient supply reliability. Existing flexible interconnection solutions mostly employ AC–DC–AC back-to-back converter architectures, which suffer from high cost, large footprint, and low efficiency. To address these issues, this paper proposes a flexible AC controllable interconnection device based on a hybrid series–parallel structure. The device couples series voltage injection through cascaded H-bridge (CHB) submodules with parallel feeding through a multi-winding transformer: the series side synthesizes a controllable AC voltage source from the cascaded submodules, enabling independent regulation of the active and reactive power of the line, while the parallel side supplies isolated power to the DC sides of all submodules via the multi-winding transformer, thereby fundamentally resolving the DC-side energy-balance problem of series-connected converters. A decoupled vector control strategy in the dq synchronous rotating reference frame, together with an individual-phase control scheme, is developed, and the device supports both interconnected and islanded operation modes. An RTDS simulation model is established on the basis of 10 kV/5 MW rated parameters, and three groups of tests are conducted: steady-state active power control, steady-state reactive power compensation, and dynamic active power control. The simulation results show that the steady-state active power control error is below 1.5%, the reactive power compensation error is approximately 5%, and the dynamic power step response time is 12–13 ms, with the power settling at the target value within 30 ms, verifying the technical feasibility and effectiveness of the proposed scheme for power-flow regulation and reactive power compensation in distribution networks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Flexible Interconnection Device-Driven Fluctuating Power Allocation Strategies in Interconnected Distribution NetworksProtection and Control of Modern Power Systems · 2026
- Hierarchical and Distributed Control of AC and DC Microgrid Clusters Interconnected by Flexible DC Distribution NetworkCSEE Journal of Power and Energy Systems · 2026
- Two-Stage Day-Ahead and Intraday Active-Power Regulation of a Flexible Distribution Network Node: Scenario-Based Stochastic Optimization and Model Predictive ControlEnergies · 2026
- Refined Fuzzy-Control-Based VSG Control Strategy for Flexible Interconnection Devices in Distribution GridElectronics · 2025
- A Path to Configurable Solid State Transformers and Energy Routers: Introduction to Modular Active Cell ControlIEEE Transactions on Power Electronics · 2025
- Fault Diagnosis, Fault Tolerance, and Reconfiguration of Cascaded H-Bridge Multilevel Converter Applications: A Comprehensive ReviewApplied Sciences · 2026