Optimal Energy Storage Capacity Sizing Method Based on Power-Energy Characteristics of Curtailment and Deficit Events
Gangui Yan, Weian Kong, Kefan Qi, Jianshu Li
Key points
From the paper's conclusion- The results show that compared with traditional empirical sizing schemes, the proposed scheme increases the complete mitigation rate of curtailment and deficit events from 32.57% to 49.01%; compared with the extreme sizing scheme that completely covers the gaps, it avoids a massive investment of nearly 380 million RMB/year.
Abstract
With the increasing penetration of renewable energy represented by wind and photovoltaic (PV) power in the power grid, the fluctuation amplitude of the net load curve is growing significantly, and the regulation capability of thermal power units can hardly accommodate such large fluctuations. When the adjustable range fails to meet the net load fluctuations, power curtailment and deficit issues arise in the system. Deploying energy storage is a common method to addressing power curtailment and deficit. However, over-sizing the storage capacity leads to low utilization of the storage equipment, while under-sizing fails to effectively mitigate the curtailment and deficit issues. Addressing the insufficiency of regulation capacity in future power systems with high wind and solar penetration, this paper proposes an optimal energy storage capacity allocation method based on the characteristics of power curtailment and deficit. First, a characterization model for the regulation capacity of existing conventional power sources is constructed. Combined with the annual wind and PV output curves, the temporal distribution of annual curtailment and deficit events is quantified based on the existing regulation capacity. Second, an optimal energy storage capacity allocation method matching the power–energy characteristics of curtailment and shortage is developed to minimize storage investment and maximize the reduction in losses caused by curtailment and deficit. Finally, the proposed method is validated based on a full-cycle operation scenario of a provincial power grid. The results show that compared with traditional empirical sizing schemes, the proposed scheme increases the complete mitigation rate of curtailment and deficit events from 32.57% to 49.01%; compared with the extreme sizing scheme that completely covers the gaps, it avoids a massive investment of nearly 380 million RMB/year. In future scenarios with gradually increasing renewable energy penetration, both the optimal charge/discharge duration and the event mitigation rate derived by the proposed scheme increase steadily, demonstrating its significant guiding value for long-term planning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Capacity optimization method for renewable energy joint energy storage based on an edge-lightweight dynamic gameInternational Journal of Pattern Recognition and Artificial Intelligence · 2026
- Design and coordinated capacity control of ESSs for typical new power system scenariosJournal of Physics: Conference Series · 2026
- Optimal Planning of Renewable Energy and Storage Considering Capacity Credit ConstraintProtection and Control of Modern Power Systems · 2026
- Bi-level optimal configuration of high-mountain photovoltaic storage systems based on adaptive deviation compensationEngineering Research Express · 2026
- The Renewable Energy Storage Gap in Europe: A Review of the Growing Asymmetry Between Generation and Storage in the European Power SystemSustainability · 2026
- Coordinated Wind–Storage Frequency Regulation Strategy for Suppressing Frequency FluctuationsEnergies · 2026