Experimental Investigation of Partial Flue Gas Recirculation During Load Changes in a 1 MWth SRF-Fired CFB Combustor
Alexander Kuhn, Jochen Ströhle, Bernd Epple
Technische Universität Darmstadt
Key points
From the paper's conclusion- This study investigates partial flue gas recirculation (FGR) as a strategy to enhance short-term load flexibility in a 1 MWth CFB pilot plant fired exclusively with solid recovered fuel.
Abstract
The increasing share of renewable energy sources in power grids demands greater load flexibility from thermal power plants. Circulating Fluidized Bed (CFB) combustion systems, while offering fuel flexibility and high thermal inertia, face challenges in maintaining hydrodynamic and thermal stability during load transitions. This study investigates partial flue gas recirculation (FGR) as a strategy to enhance short-term load flexibility in a 1 MWth CFB pilot plant fired exclusively with solid recovered fuel. Two experimental test series were conducted. Under conventional operation, where fuel and fluidization air are reduced proportionally, load reductions to 86% and 80% led to operating regime shift. Particle entrainment from the riser to the freeboard and loop seal decreased, circulation weakened, and the temperature difference between bed and freeboard zone increased by 71 K. Grace diagram analysis confirmed that the system approached the boundary of the circulating regime. In contrast, the partial FGR strategy maintained total fluidization rates by replacing part of the combustion air with recirculated flue gas. This stabilized pressure conditions, sustained particle circulation, and limited the increase in the temperature difference to just 7 K. Heat extraction in the freeboard remained constant or improved, despite slightly lower flue gas temperatures. While partial FGR introduces a minor efficiency loss due to the reheating of recirculated gases, it significantly enhances combustion stability and enables low-load operation without compromising fluidization quality. These findings demonstrate the potential of partial FGR as a control strategy for flexible, waste-fueled CFB systems and supports its application in future low-carbon energy systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of flue gas recirculation on combustion stability and pollutant formation in a 300 MW utility CFB boiler under ultra-low-load operation: A numerical study accounting for non-gray gas radiationFuel Processing Technology · 2026
- Characteristics of ultra-low load and flexible peak shaving – a study on circulating fluidized bed preheating combustionFuel · 2025
- Dynamic modeling and scenario analysis of a 2 MWth circulating fluidized bed gasifierFuel · 2026
- A system-level dynamic model for gasification process: Steady-state experimental validation and load-change predictionsEnergy · 2026
- A Study on Dynamic Analysis and Operational Optimization of an F-Class Combined-Cycle Power Plant Under Seasonal Load ConditionsApplied Sciences · 2026
- Structural Optimization of the Vortex Finder in Cyclone Separators of Circulating Fluidized Bed BoilerJurnal Syntax Transformation · 2026