Electronics

Dispatch-Preserving Capability-Aware Coordination of Distributed Grid-Forming Hybrid Energy Storage in Active Distribution Networks

Wenming Jiang, Xiangyang An, Yanjun Chen, Maoyu Wu, Guanda Chen, Wenshan Hu, Xiaoran Dai

Key points

From the paper's conclusion
  • The results demonstrate coordinated voltage support, capability-aware dispatch preservation, and improved communication resilience within the examined operating conditions.

Abstract

Distributed grid-forming hybrid energy storage systems (GFM-HESSs) can provide fast voltage support in active distribution networks, but autonomous local support may conflict with feeder-level aggregate dispatch and becomes more difficult under heterogeneous device capabilities and communication outages. This paper proposes a dispatch-preserving capability-aware coordination framework for distributed GFM-HESSs. Local active- and reactive-power support references are first generated from AC power-flow voltage sensitivities. The resulting active-power contribution is then separated from the feeder-level command, and the residual dispatch is allocated according to instantaneous power headroom and battery energy margin, with active-set redistribution handling unit saturation. A communication-optional mechanism further retains local voltage support while progressively withdrawing the coordinated component during communication loss. Studies on a modified IEEE 33-bus network show that the proposed method limits the maximum voltage to 1.0474 p.u. under PV-induced overvoltage and preserves the aggregate reference to numerical precision under heterogeneous HESS capabilities. In the deterministic S4 case, smooth fallback reduces the maximum reference discrepancy by 21.5%. For the 1.5-MW dispatch step, C3 reaches 90% of the command within 72 ms, although the original configuration exhibits a 51.51% overshoot. Matched-plant comparisons show that this transient response depends strongly on the lower-level GFM-HESS implementation. The tested battery–supercapacitor configuration has an approximately 53.1% lower battery power-variation index relative to the battery-only implementation. Communication stress tests identify operating conditions in which voltage violations can still occur. The results demonstrate coordinated voltage support, capability-aware dispatch preservation, and improved communication resilience within the examined operating conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Dispatch-Preserving Capability-Aware Coordination of Distributed Grid-Forming Hybrid Energy Storage in Active Distribution Networks — Science Skim