Electronics

Wideband Oscillation Stability Assessment of Renewable Energy Power Plants Based on Data–Model Fusion

Jinzhong Li, Yuguang Xie, Zhe Li, Cunyu Wang, Bao Xie, Yan Du

Key points

From the paper's conclusion
  • The findings reveal the influence of unit electrical locations and collector-network topology on plant-level wideband stability, providing a theoretical reference for operating-mode adjustment and power-output topology optimization in renewable energy power plants.

Abstract

With the increasing penetration of renewable energy generation, dynamic interactions among converter control loops, filters, and grid impedance have become increasingly complex, making wideband oscillation stability a critical concern in renewable energy power plants. This study investigates electromagnetic wideband oscillation stability associated with converter control dynamics, converter–grid impedance interactions, and multi-unit coupling, focusing on the frequency range of 1–3000 Hz. To address the difficulty in accessing the internal control structures and parameters of commercial renewable energy generation units, a data–model fusion approach is employed for plant-level wideband stability assessment. First, a backpropagation (BP) neural network-based admittance identification model is developed using terminal voltage, current, and frequency-sweeping data under different active-power operating conditions, thereby establishing a nonlinear mapping between operating conditions and wideband dq admittance. The identification accuracy and generalization capability of the model are evaluated using the model-development dataset and an independent test dataset, respectively. Second, the offline-trained data-driven unit models are integrated with the physical electrical topology model of the renewable energy power plant. Through admittance transformation between local and global reference frames and impedance-network aggregation based on the nodal admittance matrix, the plant-level wideband equivalent impedance is obtained, and its stability is evaluated using the generalized Nyquist criterion. Based on this approach, a renewable energy power plant comprising 15 photovoltaic generation units is investigated, with particular emphasis on the effects of unit electrical locations and collector-network topology variations on plant-level equivalent impedance characteristics and stability margins. The results demonstrate that variations in unit electrical locations and feeder configurations significantly alter the equivalent impedance characteristics and stability margins of the power plant. The findings reveal the influence of unit electrical locations and collector-network topology on plant-level wideband stability, providing a theoretical reference for operating-mode adjustment and power-output topology optimization in renewable energy power plants.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Wideband Oscillation Stability Assessment of Renewable Energy Power Plants Based on Data–Model Fusion — Science Skim