Wideband Oscillation Stability Assessment of Renewable Energy Power Plants Based on Data–Model Fusion
Jinzhong Li, Yuguang Xie, Zhe Li, Cunyu Wang, Bao Xie, Yan Du
Key points
From the paper's conclusion- The findings reveal the influence of unit electrical locations and collector-network topology on plant-level wideband stability, providing a theoretical reference for operating-mode adjustment and power-output topology optimization in renewable energy power plants.
Abstract
With the increasing penetration of renewable energy generation, dynamic interactions among converter control loops, filters, and grid impedance have become increasingly complex, making wideband oscillation stability a critical concern in renewable energy power plants. This study investigates electromagnetic wideband oscillation stability associated with converter control dynamics, converter–grid impedance interactions, and multi-unit coupling, focusing on the frequency range of 1–3000 Hz. To address the difficulty in accessing the internal control structures and parameters of commercial renewable energy generation units, a data–model fusion approach is employed for plant-level wideband stability assessment. First, a backpropagation (BP) neural network-based admittance identification model is developed using terminal voltage, current, and frequency-sweeping data under different active-power operating conditions, thereby establishing a nonlinear mapping between operating conditions and wideband dq admittance. The identification accuracy and generalization capability of the model are evaluated using the model-development dataset and an independent test dataset, respectively. Second, the offline-trained data-driven unit models are integrated with the physical electrical topology model of the renewable energy power plant. Through admittance transformation between local and global reference frames and impedance-network aggregation based on the nodal admittance matrix, the plant-level wideband equivalent impedance is obtained, and its stability is evaluated using the generalized Nyquist criterion. Based on this approach, a renewable energy power plant comprising 15 photovoltaic generation units is investigated, with particular emphasis on the effects of unit electrical locations and collector-network topology variations on plant-level equivalent impedance characteristics and stability margins. The results demonstrate that variations in unit electrical locations and feeder configurations significantly alter the equivalent impedance characteristics and stability margins of the power plant. The findings reveal the influence of unit electrical locations and collector-network topology on plant-level wideband stability, providing a theoretical reference for operating-mode adjustment and power-output topology optimization in renewable energy power plants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis and Mitigation of Wideband Oscillations in PV-Dominated Weak Grids: A Comprehensive ReviewProcesses · 2025
- A Wideband Oscillation Classification Method Based on Multimodal Feature FusionElectronics · 2026
- Enhanced control of energy storage converter for stabilizing renewable energy integrated systemsInternational Journal of Electrical Power & Energy Systems · 2026
- Clustering-Based Equivalence Modeling and Stability Analysis of Large-Scale Renewable Energy PlantsElectronics · 2026
- Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation MitigationarXiv · 2026
- Two-stage stability enhancement framework based on S-domain modal analysis for renewable energy power systemsInternational Journal of Electrical Power & Energy Systems · 2026