Topology-Constrained Binary Fault Section Location in Active Distribution Networks: An Adaptive Archimedes Optimization Algorithm
Juhao Zhang, Jian Sun
Key points
From the paper's conclusion- To address these challenges, this paper proposes a topology-constrained binary fault-location framework for active distribution networks and instantiates it with the topology-constrained adaptive binary Archimedes optimization algorithm (TCAB-AOA).
Abstract
As the penetration of distributed generation (DG) in distribution networks grows, fault currents shift from unidirectional to bidirectional flow, and fault-section location becomes difficult when feeder terminal units (FTUs) are subject to false alarms, missed detections, or false negatives. To address these challenges, this paper proposes a topology-constrained binary fault-location framework for active distribution networks and instantiates it with the topology-constrained adaptive binary Archimedes optimization algorithm (TCAB-AOA). The work corrects three modeling issues common to metaheuristic-based fault-section location: (i) the reverse-current term of the switching function is re-derived so that a downstream DG feeds a reverse current to any network fault rather than only to a fault on its own upstream path; (ii) an unavailable FTU measurement is masked and excluded from the objective rather than equated with a confirmed zero-current reading; and (iii) the FTU observations are generated by an independent nodal-impedance short-circuit model rather than by the switching function itself, so that the reported accuracy reflects generalization to a physical model rather than a self-consistent fit. On this corrected model, the framework integrates hybrid hard-intersection/soft-voting initialization, differential-evolution and Lévy-flight dual perturbation, elite preservation with population restart, and greedy cleanup. On the IEEE 33-node system under nine DG-integrated fault scenarios, TCAB-AOA attains 89.63% average localization accuracy with 0.19 average misjudged sections, significantly outperforming standard AOA (44.81%). A fair-baseline study that equips standard PSO and DE with the same topology-constrained framework yields 88.52% and 92.96%, statistically indistinguishable from TCAB-AOA (p > 0.05, Bonferroni-corrected α = 0.0083), which confirms that the accuracy gain stems primarily from the corrected model and the topology-constrained framework rather than from the specific metaheuristic. The method requires only the existing three-valued FTU upload plus a one-bit availability flag and runs in about 0.5 s per localization, making it directly deployable as a decision-support module on existing feeder-automation systems without additional sensors or communication links.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fault Detection Methods in a Power Distribution System with DER: A ReviewEnergies · 2026
- Distribution Network Reconfiguration in Active Distribution Systems Using a Discrete Adaptive Hybrid Seagull Optimization AlgorithmElectricity · 2026
- Voltage Risk Zoning and Multi-Resource Coordinated Optimization for Active Distribution Networks Under Feeder Disconnection FaultsSustainability · 2026
- Scenario-Aware Feeder Grouping with Transfer-Path Preservation for Post-Fault Load Restoration Using Graph Neural NetworksElectronics · 2026
- A Novel Distribution Network Reconfiguration Method with the Power Forecasting of DGsElectronics · 2026
- Performance evaluation of advanced metaheuristic algorithms for directional overcurrent relay coordination in distribution networksScientific Reports · 2025