An H-Bridge-Based Battery ACIR Measurement System with Energy Recovery
Xiaobing Lao, Zhaohui Jin, Jingying Xie, Liqin Yan, Cheng Wang, Liqun He, Atif Iqbal, Kefu Liu,
Key points
From the paper's conclusion- After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings.
Abstract
Conventional battery alternating current internal resistance (ACIR) measurement faces challenges in generating adjustable high-current excitation with low energy dissipation and accurately acquiring weak alternating current (AC) voltage responses. This paper proposes an H-bridge-based battery ACIR measurement system with energy recovery. The battery under test directly supplies the excitation energy, enabling bidirectional energy transfer through the H-bridge and an energy-storage inductor. Fixed-frequency phase-shift modulation generates amplitude-adjustable bidirectional test currents at 1 kHz. An active direct current (DC) offset-cancelation sensing architecture improves analog-to-digital converter (ADC) input-range utilization for millivolt-level AC voltage responses, while a single-bin discrete Fourier transform (DFT) extracts the 1 kHz fundamental components for ACIR calculation. At measured peak test currents of 20, 100, and 400 mA, the charge return ratios were 8.53%, 9.81%, and 12.49%, respectively. Under the constant-terminal-voltage approximation, these values also estimate the fraction of energy drawn from the battery that was returned to it during the same excitation cycle. During 15 min repeated measurements, the proposed system exhibited lower apparent temperatures than the comparison instruments under the respective test conditions, with no detectable change in battery open-circuit voltage at the reported resolution. For the same conditioned signal, the 1 kHz fundamental voltage amplitude obtained from the ADC samples was 2.34% lower than the oscilloscope result. After channel calibration, the proposed system measured the 1 kHz ACIR of seven lithium-ion cells using the 20 and 100 mA excitation settings. Across the seven cells, the maximum and mean absolute relative deviations were 3.50% and 1.60%, respectively, relative to the VICTOR 3540, and 2.65% and 1.26%, respectively, relative to the FNIRSI HRM-10.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Excitation Signal Design for Fast Electrochemical Impedance Spectroscopy in Battery TestingBatteries · 2025
- Economic trade-off of regenerative braking in hybrid vehicles: recovered-energy value versus accelerated battery degradation, with a worked case study for Turkish operating conditionsInternational Journal of Automotive Engineering and Technologies · 2026
- Real-time impedance spectroscopy of lithium-ion batteries via composite current pulsesJournal of Energy Chemistry · 2026
- State of Charge Estimation of Lithium-Ion Battery Based on RBMO and Iterative H-Infinity FilterEnergies · 2026
- Integrated Control of Battery and Ultracapacitor in Electric Vehicles With Regenerative BrakingInternational Journal of Energy Research · 2026
- The Dynamic Response Index: Non-intrusive extraction of proton exchange membrane fuel cell aging signatures from 1-Hz transientsJournal of Power Sources · 2026