Sizing a Stand-Alone Wind–Photovoltaic DC Microgrid for Offshore Aquaculture: Delivered Energy, Load Coverage and Storage Requirements
Yifei Zhang, Gang Mu, Hui Cao, Fuhai Duan
Key points
From the paper's conclusion- We size such a supply for an offshore cage farm in the northwestern Yellow Sea and test it against ten years of hourly reanalysis data.
Abstract
Whether a stand-alone wind–photovoltaic supply is adequate depends more on how its load is described than on how it is rated. Sizing starts from component ratings and a peak load, yet the annual energy balance that follows says nothing about whether the load is served in every hour, and one installation can look comfortable under one description of its duty and insufficient under another. We size such a supply for an offshore cage farm in the northwestern Yellow Sea and test it against ten years of hourly reanalysis data. The annual margin over a monitoring and control load is wide, while the same hardware meets only a small part of a demand that draws full power continuously. The hourly simulation qualifies the first verdict: part of the critical demand is unserved, the longest lull outlasts the battery, and added storage closes the gap slowly. The site’s two resources are out of phase but only weakly complementary, so generation and storage must be sized for the wind season alone. The resource carries the uncertainty. Annual adequacy establishes a margin rather than continuity, and the storage is set by the load-duration curve.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Energy Storage for Off-Grid Communities: A Structured Global Inventory of 2348 Real Sites, Multi-Criteria Comparison, and Site-Specific RecommendationsEnergies · 2026
- Field Evaluation of a Photovoltaic–Wind Turbine–Battery DC Microgrid with a Concentrated Solar Thermoelectric BranchEnergies · 2026
- Robust Multi-Objective Sizing and Operation of an Autonomous Bifacial Photovoltaic Water-Supply Pumping SystemEnergies · 2026
- Regulation of Surplus Electricity in an Off-Grid Photovoltaic SystemMATEC Web of Conferences · 2026
- Demand-Profile Effects on PV Self-Consumption and Battery Storage Performance: Five Mediterranean Case StudiesEnergies · 2026
- Least-Cost Sizing and Multi-Criteria Assessment of Hybrid Solar–Wind–Hydrogen Systems Under Climate–Resource Sensitivity ScenariosEng · 2026