Electronics

Integrated Turboshaft FADEC Architecture and the Effect of Governor Implementation on Protection-Layer Loading

Masoud Norouzi, Ismail Bayezit, Mahmut Reyhanoglu

Key points

From the paper's conclusion
  • An integrated FADEC architecture for a GE T700-class turboshaft is developed on a nonlinear T-MATS model, combining a power turbine speed governor, a two-dimensional variable guide vane schedule, actuator and sensor dynamics with transport delays, and a seven-channel min–max protection layer.

Abstract

Comparative studies of turboshaft fuel controllers commonly report performance advantages without holding the loop bandwidth or anti-windup implementation constant across the compared configurations. This paper asks what survives such a comparison. An integrated FADEC architecture for a GE T700-class turboshaft is developed on a nonlinear T-MATS model, combining a power turbine speed governor, a two-dimensional variable guide vane schedule, actuator and sensor dynamics with transport delays, and a seven-channel min–max protection layer. Three governors (gain-scheduled PI, fixed-gain PI and integral sliding-mode) are evaluated with identical anti-windup implementations, with their loop bandwidths matched by construction at the hover operating point used for the load-disturbance tests. Transient performance is closely comparable, with overshoot during scheduled transitions differing by at most 0.25 percentage points; however, protection-layer loading is not, as the sliding-mode governor holds the limiters active for 9.2% longer than the baseline under load disturbance. Removing the anti-windup tracking path changes cumulative limiter engagement by 6.6 times the difference attributable to the control law; the ordering survives both sensor noise and a ±20% perturbation of the power turbine inertia. Within the tested architecture, the dominant coupling between speed governance and engine protection is associated with the anti-windup implementation rather than the control law. Automatic code generation yields 37% less algorithm code for the sliding-mode configuration, with software-in-the-loop verification at a fixed 5 ms step.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Integrated Turboshaft FADEC Architecture and the Effect of Governor Implementation on Protection-Layer Loading — Science Skim