Ontology-Driven Robotic UV-C Disinfection: Coupling an Active Shielding Blind with Semantic Dose Planning for Multi-Domain Deployment
Kyeongjin Joo, Eunjin Kim, Minyoung Jeong, Yunyoung Kook, Kwanghee Lee, Taeyong Kuc
Key points
From the paper's conclusion- Deployed since December 2021 at more than twenty real-world sites across the medical, transport, administrative, commercial and educational domains—of which eight are documented as demonstration sites in this paper—the platform raised the dose achievement rate of high-touch (P3) targets from 50.0% under a uniform waypoint scheme of equal mission time to 90.0% and, at equivalent achievement, shorte
Abstract
This paper proposes a semantic-based autonomous disinfection robot system for continuous operation in environments where robots coexist with people. Existing UV-C disinfection robots presuppose unoccupied-hours operation owing to their exposed lamp structures, and their uniform irradiation at predefined waypoints ignores the infection risk of individual targets. The proposed system integrates the optical blocking of UV-C and the physical protection of the lamps into a single mechanism through an active shielding blind driven by a single motor, securing the irradiation distance as a control variable for dose. On this basis, we extend the Triplet Ontological Semantic Model (TOSM) to the disinfection domain, defining semantic classes of objects and places with level-specific target doses, and derive irradiation distances and exposure times from a measured irradiance model. Deployed since December 2021 at more than twenty real-world sites across the medical, transport, administrative, commercial and educational domains—of which eight are documented as demonstration sites in this paper—the platform raised the dose achievement rate of high-touch (P3) targets from 50.0% under a uniform waypoint scheme of equal mission time to 90.0% and, at equivalent achievement, shortened the mission time by 10 min with a proportional reduction in lamp energy, while zero lamp breakages over five years of operation verify the safety and reliability of the shielding structure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Defining Operational UV-C Dose Requirements for Autonomous Disinfection of Clinically Relevant Pathogens Across Healthcare and High-Touch SurfacesbioRxiv · 2026
- Effectiveness of ultraviolet-C robots in isolation room disinfection: Impact of dose, distance, and direct exposure on environmental surface decontamination.PloS one · 2026
- Germicidal Ultraviolet C (UV-C) Light for Surface Disinfection in Hospitals: Mapping the Evidence on Devices, Parameters, Effectiveness, and ImplementationHygiene · 2026
- Radiometrically Equivalent Comparison of 254 nm Low-Pressure Mercury Lamps and InGaN 280 nm UV-C LEDs for Surface Disinfection.ACS omega · 2026
- UVC-LED Disinfection Technology: Mainstream Waveband Characteristics, Applications and ChallengesWater Air & Soil Pollution · 2026
- Robotics in Ionizing Radiation Environments: Vulnerabilities, Hardening, and Future DirectionsAdvanced Robotics Research · 2026