Triple Active Bridge Modeling and Decoupling Control
Andrés Camilo Henao-Muñoz, Mohammed B. Debbat, Antonio Pepiciello, José Luís Domínguez‐García
Institut de Recerca en Energia de Catalunya
Key points
From the paper's conclusion- Therefore, this paper presents and compares different modeling and decoupling control approaches applied to the triple active bridge converter, highlighting their benefits and limitations.
Abstract
The increased penetration of power electronics interfaced resources in modern power systems is unlocking new opportunities and challenges. New concepts like multiport converters can further enhance the efficiency and power density of power electronics-based solutions. The triple active bridge is an isolated multiport converter with soft switching and high voltage gain that can integrate different sources, storage, and loads, or act as a building block for modular systems. However, the triple active bridge suffers from power flow cross-coupling, which affects its dynamic performance if it is not removed or mitigated. Unlike the extensive literature on two-port power converters, studies on modeling and control comparison for multiport converters are still lacking. Therefore, this paper presents and compares different modeling and decoupling control approaches applied to the triple active bridge converter, highlighting their benefits and limitations. The converter operation and modulation are introduced, and modeling and control strategies based on the single phase shift power flow control are detailed. The switching model, generalized full-order average model, and the reduced-order model derivations are presented thoroughly, and a comparison reveals that first harmonic approximations can be detrimental when modeling the triple active bridge. Furthermore, the model accuracy is highly sensitive to the operating point, showing that the generalized average model better represents some dynamics than the lossless reduced-order model. Furthermore, three decoupling control strategies are derived aiming to mitigate cross-coupling effects to ensure decoupled power flow and improve system stability. To assess their performance, the TAB converter is subjected to power and voltage disturbances and parameter uncertainty. A comprehensive comparison reveals that linear PI controllers with an inverse decoupling matrix can effectively control the TAB but exhibit large settling time and voltage deviations due to persistent cross-coupling. Furthermore, the decoupling matrix is highly sensitive to inaccuracies in the converter’s model parameters. In contrast, linear active disturbance rejection control and sliding mode control based on a linear extended state observer achieve rapid stabilization, demonstrating strong decoupling capability under disturbances. Furthermore, both control strategies demonstrate robust performance under parameter uncertainty.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Small-Signal Modeling and Fixed-Gain PI Voltage Control of a Triple-Active-Bridge Converter Under Different Power Flow ConditionsVehicles · 2026
- Design and Experimental Validation of a Three-Port Unidirectional Isolated DC–DC Converter with Dual OutputsEnergies · 2026
- Composite Model Predictive Control Strategy for Triple-Active-Bridge-Based MMDTC-PET with Enhanced Disturbance ResilienceEnergies · 2026
- Topology Derivation of Integrated Three‐Port DC–DC Converters for Non‐Isolated Renewable and Hybrid Energy Storage ApplicationsInternational Journal of Circuit Theory and Applications · 2026
- Research on PV-Storage Complementary Three-Port Converter With Power DecouplingIEEE Journal of Emerging and Selected Topics in Power Electronics · 2026
- Model-free predictive control strategy for three-level dual active bridge converter based on novel sliding mode observerScientific Reports · 2026