European Burn Journal

A Narrative Review of Inhalation Injury Due to Lithium-Ion Battery Combustion

George Bond, Anna Noble, David Barnes, Naguib El-Muttardi, Chloe Vaughan, Clare Henney, Quentin Frew

Review

Key points

From the paper's conclusion
  • We propose that a structured documentation framework be developed to guide future case reporting and facilitate clinical evidence gathering, with the goal of improving clinical outcomes and reducing LIB-related inhalation injury morbidity and mortality.

Abstract

(1) Background: The widespread use of lithium-ion batteries (LIBs) in consumer electronics, electric vehicles, and e-cigarettes has led to a rise in combustion-related injuries, including serious inhalation injuries. Despite their increasing prevalence, there is limited understanding and no standardised protocol for treating inhalation injuries from LIB combustion. (2) Methods: A comprehensive literature search was conducted across MEDLINE (Ovid), EMBASE (Ovid), Cochrane Central Register of Controlled Trials (CENTRAL), CINAHL Ultimate (EBSCOhost), and Scopus using keywords related to lithium-ion batteries, inhalation burns, or inhalation injuries. Inclusion criteria consisted of English-language studies involving adult patients with confirmed inhalation injuries from LIB combustion. Seven studies published between 2019 and 2026 met the inclusion criteria. Data was collected from the USA, China, Ireland, Israel, and Singapore. (3) Results: Hydrogen fluoride (HF), a noxious gas released by damaged LIBs, was identified as a toxic chemical that, if inhaled in sufficient quantity, can cause systemic and life-threatening electrolyte changes. Nebulised calcium gluconate was proposed or administered in several studies as a potential treatment for HF-related toxicity, although direct evidence for its efficacy in HF inhalation injury specifically is lacking. Patients in the studies were mostly male, young, employed, and the LIB fires frequently occurred overnight while charging indoors. LIB fires occurred due to an exothermic reaction known as thermal runaway. Management strategies included intubation, tracheostomy, airway support, fluid resuscitation, and intensive care. There is no clear association between device size and inhalation injury, with other factors being just as important in determining patient outcome. Studies frequently emphasised prevention, user education, and policy measures, such as regulated charging practices and the use of dry-powder fire extinguishers. No data relating to LIB thermal runaway in mobile phone or laptop LIBs was found. (4) Conclusions: LIB combustion events are increasing alongside the widespread use of LIBs in an attempt to reduce pollution. Risks to health may result from the release of toxic gases, which, if inhaled, pose serious systemic health risks. The literature relating to inhalation injuries from LIBs is sparse, but studies show there is an urgent need for (i) increased awareness of inhalation injury linked to LIBs; (ii) a standardised injury classification and reporting protocol to facilitate LIB-related injury reporting and enable treatment analysis; and (iii) LIB-related inhalation injury-specific management protocols. We propose that a structured documentation framework be developed to guide future case reporting and facilitate clinical evidence gathering, with the goal of improving clinical outcomes and reducing LIB-related inhalation injury morbidity and mortality.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Narrative Review of Inhalation Injury Due to Lithium-Ion Battery Combustion — Science Skim