A Data Compression Method for Mechanical Vibration Wireless Sensor Networks Based on Data Segmentation and Non-Uniform Quantization.
Yi Huang, Jiaquan Zhang, Xiaojing Mu, Dongmei Tian, Rongtao Mu, Tianhong Luo
School of Intelligent Manufacturing, Chongqing University of Arts and Sciences, Chongqing 402160, China. · Key Laboratory of Optoelectronic Technology & Systems Ministry of Education, International R & D Center of Micro-Nano Systems and New Materials Technology, Chongqing University, Chongqing 400044, China.
Key points
From the paper's conclusion- These results demonstrate that the proposed method effectively reduces vibration data volume while preserving critical dynamic characteristics.
Abstract
High-frequency sampling in mechanical vibration wireless sensor networks (WSNs) generates large volumes of raw data, imposing substantial demands on transmission bandwidth and node energy consumption. To address this problem, this paper proposes a two-stage compression method based on data segmentation and non-uniform quantization. First, byte-level statistical characteristics of 24-bit raw analog-to-digital converter (ADC) data are analyzed. The results reveal the limitations of conventional transform-domain thresholding and show distinct statistical characteristics among different bit planes. Accordingly, each 24-bit sample is divided into an 8-bit sign-bit channel and a 16-bit content-bit channel. The sign-bit channel exhibits high temporal redundancy and is therefore compressed losslessly using variable run-length encoding (VRLE). An adaptive repetition-ratio criterion is introduced to select the encoding mode and avoid data expansion for short repetition sequences. The content-bit channel is compressed using an eight-interval non-uniform quantization scheme inspired by the A-Law PCM standard. Finer quantization is assigned to small-amplitude components to reduce reconstruction errors. Range coding is subsequently applied to both encoded streams to further remove statistical redundancy. Experiments on periodic rotor vibration signals achieve a compression ratio of 3.22 and a reconstruction signal-to-noise ratio (RSNR) of 37.4 dB. For aperiodic modal testing signals, compression ratios of 3.16 and 2.66 are obtained for force-hammer excitation and frame response signals, with RSNR values of 46.49 and 54.2 dB, respectively. Furthermore, modal identification using the reconstructed data results in a maximum relative error of only 0.03% for the first five natural frequencies. These results demonstrate that the proposed method effectively reduces vibration data volume while preserving critical dynamic characteristics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Edge-Computing Sensor Platform for ISO 2631-1 Whole-Body Vibration Exposure Metrics.Sensors (Basel, Switzerland) · 2026
- A concave-convex approach to bit depth allocation for linear MMSE estimation in wireless sensor networks with correlated noisearXiv · 2026
- Highly robust vector-synthesis method for multi-frequency distributed acoustic sensing.Optics letters · 2026
- DASPack: controlled data compression for distributed acoustic sensingGeophysical Journal International · 2025
- On the Reconstruction of Bandlimited Signals from Random Samples Quantized via Noise-ShapingConstructive Approximation · 2026
- Adaptive sub-Nyquist sampling and its application in rotating machinery fault detection.ISA transactions · 2026