Iman Makrouf, Mourad Zegrari, Khalid Dahi, Demba Diallo, Meryem Abtane, Ilias Ouachtouk
Bearing fault diagnosis increasingly relies on multiple sensors, since compound or multi-location faults can produce signatures that are only partially captured by a single sensor. The decision-level fusion (DLF) of independently trained models offers a practical way to combine such complementary information, yet systematic comparisons across DLF techniques remain scarce, particularly for measurements from different sensor locations. This paper benchmarks six DLF strategies, i.e, Max, Average, Majority Voting, Weighted Sum, Dempster-Shafer, and Stacking, on a dual-branch one-dimensional convolutional neural network (1D-CNN) with each branch trained end-to-end on vibration signals from a distinct bearing location. On a two-sensor test bench covering seven health conditions, all methods exceed 99.7% accuracy on clean signals, while Dempster-Shafer fusion proves markedly more robust under noise, retaining up to 84% accuracy at a 5 dB signal-to-noise ratio (SNR). A conflict-coefficient analysis further provides an interpretable account of when fusion succeeds, linking performance to the confidence complementarity between branches.