Key points
From the paper's conclusion- Results: The zeolite phase, metallic silver, and influence of SHMP deposition and GIC with 4 wt% Ag/TiZSM-5 particles was supported by XRD, BET, FT-IR, zeta potential, DRS-UV-vis, SEM-EDX and HR-TEM analysis.
Abstract
Background: Glass ionomer cement (GIC) is widely used as a restorative and luting material, as it possesses cariostatic features that can manage coronal and root caries. However, GIC exhibits an initial burst release of fluoride during the setting reaction, followed by gradual decline with time, limiting its long-term anticariogenic properties. Previous studies have investigated the incorporation of chlorhexidine (CHX) with hexametaphosphate. Objective: This study aimed to prepare SHMP-functionalized silver-impregnated Ti-ZSM-5 zeolite as a potential SHMP carrier and to evaluate the effect of its incorporation into GIC on the surface roughness, color change, and antimicrobial properties. Methods: Titanium-incorporated ZSM-5 zeolite was acquired from Euro Support (Czechia). The 4 wt% Ag was impregnated on Ti-ZSM-5 (4 wt% Ag/Ti-ZSM-5) using the wet impregnation technique. The resulting silver-impregnated titanium zeolite composite was mixed with sodium hexametaphosphate (SHMP) using distilled water in a 1:1 ratio by grinding into a paste, which was followed by drying. The sample was characterized using X-ray diffraction analysis (XRD), N2 adsorption-desorption, zeta potential, FT-IR, diffuse reflectance UV-visible (DRS UV-vis), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), elemental mapping and high-resolution transmission electron microscopy (TEM). Silver-impregnated titanium zeolite doped with SHMP samples was then mixed with GIC powder at ratios of 1%, 3%, and 5%, corresponding to ZSM-5@Ag/Ti 1%, ZSM-5@Ag/Ti 3%, and ZSM-5@Ag/Ti 5%. For comparison, Ag-silicalite was mixed with SHMP and GIC powder; the samples were designated as Z-Sil@Ag 1%, (F) Z-Sil@Ag 3%, and (G) Z-Sil@Ag 5% and tested for surface roughness, color change, cytotoxicity, and antimicrobial activity against Streptomyces mutans and Candida albicans. Statistical analyses were conducted using GraphPad Prism 11.1.0 and IBM SPSS Statistics 24. Normality was assessed using the Shapiro-Wilk and Brown-Forsythe tests, respectively. Group differences were evaluated using one-way and two-way ANOVA, which was followed by appropriate post hoc tests (Tukey's or Dunnett's) with effect sizes (ω2), clinical acceptability thresholds (ΔE* = 2.7) and statistical significance set at p < 0.05. Results: The zeolite phase, metallic silver, and influence of SHMP deposition and GIC with 4 wt% Ag/TiZSM-5 particles was supported by XRD, BET, FT-IR, zeta potential, DRS-UV-vis, SEM-EDX and HR-TEM analysis. Surface roughness results showed that the ZSM-5@Ag/Ti group demonstrated comparable values to those of the control group, whereas Z-Sil@Ag-3% was the only group that differed significantly from the control (p = 0.022). The ZSM-5@Ag/Ti-5% group exhibited the lowest mean color change with all groups exceeding the clinical acceptability threshold (ΔE > 2.7). All groups did not differ significantly in their antibacterial activity (p > 0.05) in comparison to the control. On one hand, the Z-Sil@Ag-5% group showed lower bacterial counts and thus higher antibacterial activity, whereas an adhesion test revealed that ZSM-5@Ag/Ti in all concentrations had the lowest counts. Conclusions: SHMP-functionalized 4 wt% Ag/TiZSM-5 could be incorporated into GIC without significantly altering its surface roughness with significant antimicrobial activity for dental applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Antibacterial and physicomechanical properties of an experimental resin infiltrant containing a novel zinc-based metal-organic framework filler.Dental materials : official publication of the Academy of Dental Materials · 2026
- Titanium Dioxide Nanoparticles-Modified Dental Glass Ionomer Cement: A Novel Approach to Enhance Cement’s Antimicrobial and Anti-BiofilmPropertiesCurrent Nanomedicine · 2026
- Bioactive performance of resin-modified glass ionomer cement functionalized with polyvalent metals and cyclic phosphates: Effects on demineralization resistance and mineralization-related cellular responses.Dental materials : official publication of the Academy of Dental Materials · 2026
- Highly Siliceous Shell-Protected Cu-Impregnated ZSM-5 Zeolite Cores for Robust Hydrocarbon Trapping.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Enhanced mechanical properties and reduced polymerization shrinkage in a light-cured flowable dental nanocomposite via incorporation of silane-functionalized ScYSZ nanoparticlesScientific Reports · 2026
- Addition of silver nanoparticle solutions to alginate: microbiological and mechanical analysis.Brazilian dental journal · 2026