Comparative Dentinal Tubule Penetration of Three Calcium Silicate-Based Sealers Under Conventional and Sonic-Activated Final Irrigation Protocols: An In Vitro Confocal Microscopy Study.
Israa Ashkar, José Luis Sanz, Leopoldo Forner, Carmen Llena, María Melo
Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain.
Key points
From the paper's conclusion- This study compared the dentinal tubule penetration of BioRoot RCS, NeoSealer Flo, and TotalFill BC Sealer with AH Plus using the calcium-sensitive fluorophore Fluo-3 and evaluated the effect of sonic activation of final irrigation.
Abstract
Background: Successful root canal treatment depends on achieving an effective three-dimensional seal and limiting microbial persistence and reinfection. Dentinal tubule penetration may enhance sealing by increasing sealer-dentin contact and micromechanical retention. This study compared the dentinal tubule penetration of BioRoot RCS, NeoSealer Flo, and TotalFill BC Sealer with AH Plus using the calcium-sensitive fluorophore Fluo-3 and evaluated the effect of sonic activation of final irrigation. Methods: 128 extracted human single-rooted teeth were allocated to four sealer groups and subdivided according to final irrigation protocol: non-activated final irrigation (NAFI) or sonic-activated final irrigation (SAFI). Sealers were labeled with 0.1% Fluo-3, and canals were obturated using the single-cone technique. Root sections obtained at 3, 5, and 8 mm from the apex were analyzed by CLSM. Penetration area and depth percentages were calculated and statistically compared (p < 0.05). Results: All sealers penetrated dentinal tubules. For overall penetration, under NAFI, BioRoot RCS and NeoSealer Flo showed significantly greater penetration area than AH Plus and TotalFill BC Sealer, while BioRoot RCS showed significantly greater penetration depth than AH Plus and TotalFill BC Sealer. Under SAFI, BioRoot RCS and NeoSealer Flo showed significantly greater penetration area than TotalFill BC Sealer, whereas NeoSealer Flo showed significantly greater penetration depth than all other sealers (p < 0.05). Sonic activation significantly increased penetration in selected sealers and root thirds; for NeoSealer Flo, penetration depth increased from 37.55% to 49.15% in the coronal third and from 33.10% to 48.73% in the middle third, while AH Plus also showed increased penetration apically and no significant effect was observed for BioRoot RCS. Penetration was generally greatest coronally and lowest apically. Conclusions: Dentinal tubule penetration was influenced by sealer type, final irrigation protocol, and root third. Sonic activation improved penetration under specific conditions but did not produce a uniform effect across all sealers or root thirds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Conventional, Laser- and Sonic-Activated Irrigation on the Sealing Ability of Root Canals Obturated with a Bioceramic Sealer: An In Vitro StudyApplied Sciences · 2026
- Dentinal tubule penetration of a bioceramic sealer after different irrigant and activation regimens: An in vitro confocal laser scanning microscopy study.Journal of conservative dentistry and endodontics · 2026
- Dentinal tubule penetration of AH Plus, MTA Fillapex, and BioRoot flow: a confocal laser scanning microscopy studyBMC Oral Health · 2025
- Evaluation of the retreatability of bioceramic root canal sealers with various formulations in simulated groovesPeerJ · 2025
- Removal of Two Ready-to-Use Calcium Silicate-Based Sealers from Artificial Grooves Using a Multisonic System and Erbium Lasers: An In Vitro Study.Journal of visualized experiments : JoVE · 2026
- Comparative Scanning Electron Microscopy (SEM) Evaluation of Advanced Irrigation Activation Techniques for Bioceramic Sealer Removal in Retreatment: An In Vitro Study.Cureus · 2026