Is Baseline Vertical Implant Positioning Relative to Adjacent Teeth Associated with Peri-Implant Outcomes? A Systematic Review and Meta-Analysis.
Paolo De Angelis, Giuseppe De Rosa, Iacopo Cioccoloni, Alberto Staffieri, Gioele Gioco, Romeo Patini, Luca Raffaelli, Carlo Lajolo
Department of Head and Neck and Sense Organs, School of Dentistry, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00168 Rome, Italy. · Private Practice, 73100 Lecce, Italy.
Key points
From the paper's conclusion- Conclusions: The available evidence is insufficient to determine whether baseline IP-CEJ or IP-ABL distances are associated with peri-implant outcomes or to identify an optimal range of vertical implant positioning.
Abstract
Background: Vertical implant positioning may influence peri-implant health outcomes and long-term stability; however, the impact of baseline vertical implant positioning relative to adjacent teeth remains unclear. The aim of this systematic review and meta-analysis was to assess the association between baseline vertical implant positioning and peri-implant clinical and radiographic outcomes. Methods: The Cochrane Central Register, PubMed, SCOPUS, and Web of Science were searched. Vertical implant positioning relative to adjacent teeth was assessed using two radiographic reference distances: implant platform to cemento-enamel junction (IP-CEJ) and implant platform to adjacent interproximal alveolar bone level (IP-ABL). The primary outcome was peri-implant marginal bone loss (MBL). Secondary outcomes included implant survival and success rates, peri-implant mucositis and peri-implantitis prevalence. Risk of bias was assessed using the Moga checklist, and certainty of evidence was evaluated according to GRADE. Results: Four studies including 267 implants fulfilled the inclusion criteria. The pooled mean baseline IP-CEJ and IP-ABL distances were 4.69 mm (95% CI 2.05 to 7.32) and 2.13 mm (95% CI 1.29 to 2.98), respectively. The pooled mean marginal bone loss after at least 12 months, based on three studies, was 0.21 mm (95% CI -0.28 to 0.70). Conclusions: The available evidence is insufficient to determine whether baseline IP-CEJ or IP-ABL distances are associated with peri-implant outcomes or to identify an optimal range of vertical implant positioning. The findings should be interpreted cautiously because the certainty of evidence is very low, highlighting the need for prospective studies with long-term follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Marginal Misfit in Implant‐Supported Fixed Dental Prostheses on Peri‐Implant Bone Levels: A Retrospective Quantitative AnalysisClinical Oral Implants Research · 2025
- Crestal bone loss and soft tissue changes in epicrestal versus subcrestal implants: An in vivo study.Bioinformation · 2026
- Association of Transmucosal Emergence Geometry and Peri‐Implant Diseases Prevalence Around Bone‐ and Tissue‐Level Implants: A Cross‐Sectional StudyClinical Oral Implants Research · 2026
- Mesial-Distal Patterns of Alveolar Bone Loss in Periodontitis and Peri-Implantitis: A Comparative Radiographic Study.Dentistry journal · 2026
- Osseointegration of dental implants: a systematic review and meta-analysis of evidence from preclinical animal models and human studies.Cell and tissue banking · 2026
- Marginal Bone Remodeling and Peri-Implant Inflammatory Biomarkers Around Crestally Placed Tissue-Level and Subcrestally Placed Bone-Level Implants: A Prospective Randomized Study.Journal of functional biomaterials · 2026