A Mask-Conditioned Deep-Learning Framework with Quantitatively Evaluated Attention for Benign–Malignant Classification of Breast Ultrasound Images
Noora Ismail Abed Al-Latif Shawareb, Amani Yousef Owda
Key points
From the paper's conclusion- We added bootstrap confidence intervals and paired tests, validation-selected operating points, a three-seed ROI-only comparison, zeroed and automatic masks, external BUSI testing with near-duplicate analysis, and quantitative Grad-CAM metrics with center-prior controls.
Abstract
Background/Objectives: Reading breast ultrasound depends strongly on the radiologist, and classifiers that rarely explain their predictions can be right for the wrong reason. We studied a classifier that receives the lesion mask as an extra input channel and how much its performance depends on that mask. Methods: EfficientNet-B3 received the RGB image and the lesion mask as a fourth channel on BUS-BRA (1875 images, 1064 patients; patient-level 70/15/15 split). We added bootstrap confidence intervals and paired tests, validation-selected operating points, a three-seed ROI-only comparison, zeroed and automatic masks, external BUSI testing with near-duplicate analysis, and quantitative Grad-CAM metrics with center-prior controls. Results: With the expert mask, accuracy was 0.870 and AUC 0.903 (95% CI 0.844–0.952) on BUS-BRA, and AUC 0.971 on BUSI. With an automatic mask the AUC fell to 0.849 (−0.054), and to 0.847 with the mask zeroed. The mask channel gave no AUC gain over ROI-only on BUS-BRA (−0.004) but did on BUSI (+0.057) and in the reverse direction (+0.077). Grad-CAM localization was not consistently better than a center prior. Sensitivity targets of 90% and 95% were not reached (0.773, 0.875). Conclusions: The design works well with expert masks and helps under distribution shift, but not with automatic masks; Grad-CAM gives only weak support for lesion-focused attention. It is a research prototype; domain-shift-robust mask generation and independent expert validation are needed. The code, weights and splits are public.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- UGB-SegNet: Uncertainty-Guided Multi-Scale Attention and Boundary-Aware Learning for Breast Ultrasound Lesion SegmentationmedRxiv · 2026
- Development of an Explainable Deep Learning Model Based on Morphological Component Analysis (MCA) for Breast Cancer Detection in Ultrasound ImagesAfrican Journal Of Applied Research · 2026
- RV-Net: Lesion-Mask-Supervised Two-View Mammography Classification at the Breast Level with Patient-Disjoint Evaluation on CBIS-DDSM and CMMDBioengineering · 2026
- XBusNet: Text-Guided Breast Ultrasound Segmentation via Multimodal Vision–Language LearningDiagnostics · 2025
- Cross-modal attention fusion of ultrasound imaging and clinical tabular data for breast lesion classification: A multimodal deep learning frameworkScientific Reports · 2026
- Automated Segmentation of Mass Lesions in Mammography: Mask R-CNN Versus Classical Methods, Fuzzy Clustering and MedSAM.Diagnostics (Basel, Switzerland) · 2026