Weakly Supervised Learning for HER2 Scoring in Cervical Cancer via Cross-Modal Knowledge Distillation: An Attentive Multi-Contrastive Alignment Framework Guided by Paired H&E and HER2 IHC Whole-Slide Images
Tao Hu, Qian Liu, Miao Wu
Key points
From the paper's conclusion- Conclusions: These findings suggest that paired IHC and H&E WSIs may provide useful training supervision for HER2 score prediction from H&E WSIs.
Abstract
Background/Objectives: Cervical cancer continues to pose a substantial global health burden, underscoring the need for accurate and early diagnostic tools. Although existing studies have demonstrated the feasibility of directly predicting human epidermal growth factor receptor 2 (HER2) scores from hematoxylin and eosin (H&E) whole-slide images (WSIs), the accuracy of these predictions remains limited. In this study, we investigated whether case-matched pairs of HER2 immunohistochemistry (IHC) WSIs and H&E WSIs can improve the HER2 score prediction. Methods: Case-matched pairs of H&E and HER2 IHC WSIs were independently encoded to generate separate sets of patch-level features. Then, within each patient-level cross-validation fold, a fold-specific HER2 IHC teacher was trained using only the IHC WSIs and labels from the four training folds and then frozen to guide a tumor-aware H&E student model through prediction distillation and multi-modal attentive contrastive learning between high- and low-attention patch groups. At the inference stage, the H&E student model predicted HER2 scores without any IHC input. Results: On the independent 126-case internal test set, under H&E-only inference, the proposed residual-fusion model trained on case-matched pairs of HER2 IHC and H&E WSIs achieved an accuracy of 0.6255, a macro-AUC of 0.6218, and a macro-F1 of 0.6103. By comparison, the model trained and evaluated using H&E-only WSIs achieved 0.5654, 0.5974, and 0.5465, respectively. In the separate IHC-assisted setting, when trained and evaluated on both H&E and IHC WSIs, the proposed residual-fusion model achieved an accuracy of 0.8080, a macro-AUC of 0.8685, and a macro-F1 of 0.7852. Although accuracy and macro-F1 were higher for the paired-training configuration under H&E-only inference, the macro-AUC remained modest. Conclusions: These findings suggest that paired IHC and H&E WSIs may provide useful training supervision for HER2 score prediction from H&E WSIs. Before clinical implementation can be considered, the model should be further evaluated in larger, independent, preferably multicenter external cohorts to assess its robustness and generalizability across institutions, scanners, staining protocols, and patient populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RNA-guided contrastive learning enhances patient-level prediction from histologybioRxiv · 2026
- Fully Automated Stain Quantification Framework for IHC Whole Slide Images in Breast CancerTechnology in Cancer Research & Treatment · 2026
- Tumor-Aware Unsupervised Digital HER2 Immunohistochemistry via Dual Contrastive Learning.Biosensors · 2026
- Deep generative virtual staining for breast cancer: from H&E histology to HER2 immunohistochemistry.BMC medical imaging · 2026
- Automatic grading of HER2 immunohistochemical whole-slide images based on a multi-scale hierarchical graph neural network.Frontiers in public health · 2026
- MLFRNet: Multi-Scale Local Feature Refinement Network Using Multi-Scale Depthwise Convolution for HER2 Score Classification.Diagnostics (Basel, Switzerland) · 2026