Diagnostics

Diagnostic Accuracy of a Simplified Four-Field Point-of-Care Ultrasound Protocol for Pulmonary Contusion in Blunt Chest Trauma

Amanda S. Fang, Soheil Saadat, Andy Hsueh, Megan Guy, Alyssa Nguyen-Phuoc, Joshua Wasmund, Edmund Hsu, Jessa Baker,

Observational · n=90

Key points

From the paper's conclusion
  • Background/Objectives: Pulmonary contusion (PC) is commonly seen in blunt chest trauma cases in the emergency department (ED).

Abstract

Background/Objectives: Pulmonary contusion (PC) is commonly seen in blunt chest trauma cases in the emergency department (ED). A PC is indicative of respiratory complications, necessitating early patient diagnosis and management. Point-of-care ultrasound (POCUS) offers a quick bedside imaging modality to assess for injuries such as PC. This study aims to evaluate the diagnostic accuracy of a simplified POCUS protocol in detecting PC compared to computed tomography (CT) in blunt chest trauma patients. Methods: We conducted a single-center prospective study from October 2021 to November 2025 at the University of California, Irvine Medical Center ED, with 90 patients analyzed. A convenience sample was utilized. Research associates conducted the screening process (e.g., 18–60 years of age; stable trauma status). An available medical student, emergency medicine (EM) resident, EM fellow, or EM attending performed the bedside POCUS procedure using the Mindray TE7ACE machine and was blinded to the clinical examination, CT results, and chest radiograph. A simplified lung ultrasound protocol was used to examine four lung fields—bilateral anterior and posterior—for the number of B-lines. POCUS findings were compared to chest CT results, which was the reference standard, and three or more B-lines in any lung field on POCUS were considered positive for PC in the setting of blunt trauma. Results: Ninety patients (mean age 32.9 years, SD 12.1) were analyzed, 37.8% of whom were female. Motor vehicle collisions were the most common trauma mechanism. Twenty-two patients had PC on CT. The prevalence of PC was 24.4%. In comparing POCUS to CT results, 18 true positives, 55 true negatives, 4 false negatives, and 13 false positives were identified. POCUS demonstrated a sensitivity of 81.8% (95% CI: 59.7–94.8%) and specificity of 80.9% (95% CI: 69.5–89.4%) in detecting PC. Its positive predictive value was 58.1% (95% CI: 39.1–75.5%), and its negative predictive value was 93.2% (95% CI: 83.5–98.1%). Conclusions: POCUS demonstrated moderately high sensitivity and specificity in detecting PC. While POCUS serves as a useful screening tool during the initial trauma assessment, findings do not establish a replacement of CT, and a positive POCUS result can prompt closer monitoring at the cost of monitoring those without PC, highlighting a trade-off between early detection and resource utilization.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers