Report-Supervised Vision-Language Alignment for Label-Efficient Bronchoscopic Finding Recognition.
İlkay Sibel Kervancı
Department of Computer Engineering, Faculty of Engineering, Gaziantep University, 27310 Gaziantep, Türkiye.
Key points
From the paper's conclusion- Results: Without training on finding labels, alignment raised zero-shot macro AUPRC from 0.184 to 0.255–0.278 and macro AUC-ROC from 0.59 to 0.77–0.78, and the gain held across ten prompt formulations.
Abstract
Background/Objectives: Fine-grained annotation of bronchoscopic findings is costly, whereas every bronchoscopic image is already described in the examination report. This single-centre proof-of-concept study investigated whether routine report text can serve as supervision for bronchoscopic finding recognition. Methods: BiomedCLIP was aligned with the image-caption pairs of the publicly available Bronchoscopy Examination Report Dataset (BERD; 4826 training images) using standard contrastive learning, a caption-aware objective that treats identical captions as positives, and a label-aware reference. The encoders were evaluated on the official test set, excluding three images duplicated from the training set (313 images, 180 patients), for zero-shot recognition of 23 report-derived finding categories, cross-modal retrieval, linear probing with 1-100% of the labelled training patients, and fine-tuning, using a hierarchical patient-level bootstrap and three training seeds. Results: Without training on finding labels, alignment raised zero-shot macro AUPRC from 0.184 to 0.255-0.278 and macro AUC-ROC from 0.59 to 0.77-0.78, and the gain held across ten prompt formulations. Retrieval generalised to captions never seen during training. With 1-25% of the labelled patients, linear probes on report-aligned features outperformed DINOv2, Swin-T and pretrained BiomedCLIP; with 5%, they exceeded DINOv2 and Swin-T trained with all labels. Caption-aware training showed no measurable benefit over standard contrastive training, full fine-tuning did not improve macro F1, and absolute performance remained modest (macro F1 at most 0.32). Conclusions: In this single-centre dataset, report text was an effective source of supervision for recognising report-derived finding categories with few labels; independent reference standards and external validation are needed before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Findings-aware Language-Image Pretraining for CT Volume InterpretationarXiv · 2026
- Binding Text to Pixels: A Narrative Review of Supervision Granularity in Language-Guided Chest Radiograph Segmentation and Grounding.Journal of imaging · 2026
- ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation LearningarXiv · 2026
- Grounding Radiology Report Findings into Medical Image Segmentation.NPJ digital medicine · 2026
- EviGround-CT: Sentence-to-Volume Grounding for Verifying LLM-Generated Chest CT ReportsarXiv · 2026
- Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CTarXiv · 2026