Key points
From the paper's conclusion- Conclusions: The integrated laboratory workflow supported rapid initial TB diagnosis while maintaining culture and drug-resistance testing capacity.
Abstract
Background: Tuberculosis (TB) diagnosis relies on the coordinated use of rapid molecular testing, microscopy, culture, and drug-resistance assays. This study evaluated laboratory performance and turnaround time (TAT) across an integrated TB diagnostic workflow in Colón Province, Panama, and compared Ziehl-Neelsen (ZN) and auramine-rhodamine microscopy. Methods: A retrospective laboratory-based study included 501 unique patients with positive Xpert MTB/RIF Ultra results between January 2021 and December 2025. The routine workflow included ZN microscopy, Xpert MTB/RIF Ultra, BD BACTEC MGIT 320 culture, and post-culture GenoType MTBDRplus testing. A separate microscopy analysis included 300 specimens with sufficient residual material for paired ZN and auramine-rhodamine staining, using Xpert MTB/RIF Ultra as the reference comparator. Results: ZN microscopy was positive in 96.4% (483/501) of Xpert-positive specimens, and ZN positivity increased significantly across Xpert semiquantitative categories (p for trend < 0.001). Among specimens with final positive MGIT cultures, increasing Xpert semiquantitative category was strongly associated with shorter MGIT TAT (Spearman's ρ = -0.728, p < 0.001). Initial MGIT contamination occurred in 5.2% (25/480) of cultures; cultures recovered after contamination had a longer median TAT than those without initial contamination (24 vs. 16 days, p < 0.001). Auramine-rhodamine microscopy showed higher sensitivity than ZN microscopy [96.8% (95% CI, 92.8-98.6) vs. 88.0% (95% CI, 82.0-92.2)] and stronger agreement with Xpert [κ = 0.967 (95% CI, 0.938-0.996) vs. 0.874 (95% CI, 0.819-0.928)]. Conclusions: The integrated laboratory workflow supported rapid initial TB diagnosis while maintaining culture and drug-resistance testing capacity. Molecular bacterial burden was associated with smear positivity and culture TAT, while fluorescence microscopy showed improved performance relative to ZN microscopy. Culture recovery procedures preserved diagnostic yield despite delays related to contamination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Implementation of in-house Xpert MTB/RIF Ultra testing reduces diagnostic turnaround time and modeled airborne isolation costsAntimicrobial Stewardship & Healthcare Epidemiology · 2026
- Technological evolution and reduction in diagnostic turnaround time of extrapulmonary tuberculosis: a 20-year analysis in a reference laboratory.Diagnostic microbiology and infectious disease · 2026
- AI-assisted tuberculosis smear microscopy in a low-incidence hospital laboratory yields incremental diagnostic improvement alongside measurable workflow efficiency.Diagnostic microbiology and infectious disease · 2026
- Validation of an AI-Driven Sputum Analysis Platform for Accurate and Reliable Tuberculosis Detection in South-Western Uganda.Medical devices (Auckland, N.Z.) · 2026
- Clinical utility of targeted next-generation sequencing for rapid detection, species differentiation, drug resistance profiling, and prognostic evaluation in Mycobacterium tuberculosis: a multi-center retrospective cohort study.Frontiers in cellular and infection microbiology · 2026
- Association of Pluslife MiniDock MTB time-to-positivity with tuberculosis bacterial load: a diagnostic study in IndonesiamedRxiv · 2026