AI-Assisted Follow-Up MRI Interpretation in Multiple Sclerosis: Radiology Residents' Diagnostic Confidence and Performance.
Milica Mastilovic, Artur Tomlinson, Wend-Yam Mohamed Traore, Marwa Alkatheeri, Igor Romčević, Jasmina Boban, Veronica Muñoz-Ramírez, Marie Blanchere,
Laboratoire d'Imagerie Biomédicale Multimodale (BioMaps), Université Paris-Saclay, CEA-Commissariat à L'Energie Atomique et aux Energies Alternatives, CNRS-Centre National de la Recherche Scientifique, Inserm, Service Hospitalier Frédéric Joliot, 91401 Orsay, France. · Department of Radiology, APHP-Assistance Publique-Hôpitaux de Paris, Hôpitaux Raymond-Poincaré & Ambroise Paré, 75000 Paris, France.
Key points
From the paper's conclusion- Conclusions: In these four residents, the AI-assisted second reading was associated with higher confidence and average accuracy.
Abstract
Background/Objectives: Artificial intelligence (AI) tools are becoming increasingly utilised in everyday radiological practice. Evaluating follow-up magnetic resonance imaging (MRI) of patients with multiple sclerosis (MS) is challenging. The aim of this study was to assess changes in confidence among four participating radiology residents when evaluating follow-up MRIs of MS patients using Pixyl.Neuro.MS® software. Methods: This retrospective study included 78 MS patients. Previous and new FLAIR images were independently analysed by four residents, first without AI and then in an immediate AI-assisted second reading using Pixyl.Neuro.MS®, a deep-learning lesion-segmentation software. Readers recorded their findings and confidence after each reading and rated the impact and usefulness of AI. The reference standard was defined by a consensus reading of a neuroradiologist and a radiology resident (15 and 4 years of experience). Paired analyses and patient-level bootstrap confidence intervals were used; bootstrap inference was conditional on the four readers. Results: The reference standard identified 24 patients with new lesions. Mean accuracy across readers increased from 84.62% to 90.71% (difference, 6.09 percentage points; 95% bootstrap confidence interval [CI], 2.24-10.26). Only Reader 3 showed a significant accuracy increase after Holm adjustment (p = 0.025). No accuracy comparison with routine reports was significant after adjustment. Confidence increased for all readers (all Holm-adjusted p < 0.001). Perceived usefulness did not differ significantly between lesion-burden groups. All readers predominantly rated the impact of AI as positive. The second-reading phase was shorter by a mean of 59.35 s (95% bootstrap CI, 51.39-67.07). Conclusions: In these four residents, the AI-assisted second reading was associated with higher confidence and average accuracy. The immediate sequential design prevents separation of AI contributions from familiarity and order effects, and the shorter second-reading phase does not establish an overall workflow time saving.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-assisted longitudinal MRI assessment in multiple sclerosis: diagnostic performance and reduction in reporting time.Neuroradiology · 2026
- A Belgian study assessing relapsing multiple sclerosis activity through automated magnetic resonance imaging volumetry.Neurodegenerative disease management · 2026
- Artificial intelligence-driven multiple sclerosis diagnosis using genomic and medical imaging data: a review.Frontiers in medicine · 2026
- Deep Learning-Based Multiple Sclerosis Lesion Segmentation at 7 Tesla: Comparison of Single- and Multi-Contrast MRI Inputs.Journal of imaging · 2026
- Deep learning in imaging analysis for multiple sclerosis: Diagnosis and monitoring.Caspian journal of internal medicine · 2026
- Performances of experts and automated methods on new multiple sclerosis lesions detection: insights from the MSSeg2 challengeScientific Reports · 2026