Diagnostics (Basel, Switzerland)

Supine Slow Vital Capacity as a Screening Test for Ultrasound-Defined Hemidiaphragm Dysfunction, with Exploratory Right-Versus-Left Comparisons.

Taro Minami, Patrick Koo, F Dennis McCool, Charles B Eaton, Mary B Roberts, Shigeki Fujitani

Division of Pulmonary, Critical Care, and Sleep Medicine, Department of Medicine, Kent Hospital, Care New England, Warwick, RI 02886, USA. · College of Medicine, University of Tennessee Health Science Center, Chattanooga, TN 37403, USA.

Key points

From the paper's conclusion
  • Conclusions: In referred adults, a supine SVC above about 80% predicted may identify patients in whom ultrasound-defined dysfunction is unlikely, although a negative likelihood ratio ≤ 0.1 was not demonstrated with confidence; inability to lie flat should itself prompt ultrasound.

Abstract

Background/Objectives: It is uncertain which widely available pulmonary function parameter best identifies hemidiaphragm dysfunction. We assessed how pulmonary function parameters agree with ultrasound-defined dysfunction and explored right-versus-left differences. Methods: We retrospectively studied 125 adults referred for suspected diaphragm dysfunction who underwent diaphragm ultrasound and pulmonary function testing, including seated and supine slow vital capacity (SVC) and maximal respiratory pressures. Dysfunction was defined as a diaphragm thickening fraction below 20%. Analyses included the area under the receiver-operating-characteristic curve (AUC), internal validation, fixed thresholds and intention-to-diagnose. Results: Forty-eight patients (38%) had dysfunction. Supine SVC had the highest AUC (0.837; 95% CI 0.761-0.904). Below a fixed threshold of 80% predicted, sensitivity was 98% (47/48), specificity 58% and the negative likelihood ratio 0.036 (95% CI 0.005-0.25). Validated sensitivity of the data-derived 78% cut-off depended on the method, because the Youden index was nearly flat: 95% (65-98%) after optimism correction, 71% by leave-one-out and 94% with a sensitivity-targeted rule. Supine SVC was unobtainable in 23% of encounters; counting these as positive, sensitivity was 98-99% and specificity 38-44%. Right-versus-left differences were inconsistent. Conclusions: In referred adults, a supine SVC above about 80% predicted may identify patients in whom ultrasound-defined dysfunction is unlikely, although a negative likelihood ratio ≤ 0.1 was not demonstrated with confidence; inability to lie flat should itself prompt ultrasound. External validation is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers