Analytical Comparison of Two Real-Time RT-PCR Assays and Development of an External Positive Control for Rotavirus A Laboratory Surveillance in Mexico.
Yessica Berenice López-Vázquez, Sergio Isaac De La Cruz-Hernández, Yazmin Anaya-Molina, Atenea Estela Andrés-Dionicio, Heidi Lizbeth Terán-Vega, Noé Escobar-Escamilla, David Esaú Fragoso-Fonseca, Gerardo Andrés Tapia-Flores,
Facultad de Estudios Superiores Cuautitlán, Universidad Nacional Autónoma de México, Avenida 10 de mayo S/N, Santa María las Torres, Cuautitlán Izcalli 54740, State of Mexico, Mexico. · Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico.
Key points
From the paper's conclusion- Therefore, they represent robust and suitable options for technology transfer to National Public Health Laboratories, supporting efforts to strengthen rotavirus surveillance in Mexico.
Abstract
Background: Rotavirus A causes diarrhea mainly in children under the age of five. Diarrhea is often nonspecific, so rotavirus detection is necessary to provide appropriate clinical care. Real-time reverse transcription-polymerase chain reaction (RT-PCR) is a sensitive, specific method that provides rapid, reliable results. Methods: Two real-time RT-PCR protocols targeting the highly conserved region of the NSP3 gene and widely used for rotavirus A detection were compared based on their analytical verification parameters. An in-house external positive control (consisting of plasmid DNA containing the viral NSP3 gene) was employed throughout the analytical verification of both real-time RT-PCR assays. Results: Reactivity results were consistent across both real-time RT-PCR protocols, showing repeatable and reproducible Ct values, with no statistically significant differences observed in the precision assays (repeatability: ∝ = 0.05, t = -1.6903, p = 0.1218; reproducibility: ∝ = 0.05, t = -1.1246, p = 0.2870). Both real-time RT-PCR protocols also detected between 14.89 and 21.65 copies of the NSP3 gene per reaction. Conclusions: These findings demonstrate equivalent performance of both assays for rotavirus A detection. Therefore, they represent robust and suitable options for technology transfer to National Public Health Laboratories, supporting efforts to strengthen rotavirus surveillance in Mexico.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bridging EIA and PCR testing results for the detection of rotavirus gastroenteritis in a US pediatric population, 2011-2016.Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2026
- An RT-qPCR Assay for Rapid Detection of Coxsackievirus A4.Viruses · 2026
- Development and validation of a multiplex real time RT-PCR assay for simultaneous detection of dengue, chikungunya and Zika viruses.Archives of virology · 2026
- A single-tube dual-channel CRISPR platform for genotyping of waterfowl reoviruses.Talanta · 2026
- Different detection rates of porcine rotaviruses in Polish commercial and family-owned farmsBMC Veterinary Research · 2026
- Simultaneous visual detection of norovirus, rotavirus, and adenovirus using multiplex reverse transcription recombinase polymerase amplification combined with lateral flow strip.Archives of microbiology · 2026