Diagnostics (Basel, Switzerland)

Comparative Diagnostic Performance of Flow Cytometry Analysis Software and Panel Configurations for Measurable Residual Disease Assessment in Pediatric BCP-ALL.

Alexandra Baldzhieva, Hasan Burnusuzov, Hristina Andreeva, Teodora Kalfova, Steliyan Petrov, Dobrina Dudova, Katya Vaseva, Marianna Murdjeva,

Department of Medical Microbiology and Immunology "Prof. Dr. Elissay Yanev", Faculty of Medicine, Medical University of Plovdiv, Vasil Aprilov Str. 15A, 4002 Plovdiv, Bulgaria. · Department of Pediatrics and Medical Genetics, Faculty of Medicine, Medical University of Plovdiv, Vasil Aprilov Str. 15A, 4002 Plovdiv, Bulgaria.

Key points

From the paper's conclusion
  • Background/Objectives: Multiparameter flow cytometry (MFC) is widely used for measurable residual disease (MRD) assessment in pediatric B-cell precursor acute lymphoblastic leukemia (BCP-ALL).

Abstract

Background/Objectives: Multiparameter flow cytometry (MFC) is widely used for measurable residual disease (MRD) assessment in pediatric B-cell precursor acute lymphoblastic leukemia (BCP-ALL). The impact of analytical software on diagnostic performance remains underexplored. Methods: We compared BD FACSDiva, FlowJo, and Infinicyt using identical Flow Cytometry Standard (FCS) datasets from 76 bone marrow samples. Routine FACSDiva MRD classification served as the reference classification. Data was analyzed using an 8-color routine panel and a 14-color extended panel. Diagnostic performance was assessed using area under the curve (AUC), sensitivity, specificity, predictive values, overall accuracy, and agreement with the reference classification. Results: The 14-color panel showed higher sensitivity, negative predictive value (NPV), and overall accuracy than the 8-color panel across all evaluated software platforms, whereas specificity varied between platforms. FlowJo with the 14-color panel showed the highest numerical diagnostic performance (AUC = 0.917; overall accuracy = 97.37%) and the strongest agreement with the reference classification (κ = 0.894; 95% confidence interval [CI] = 0.794-1.000). Its NPV was significantly higher than that of Infinicyt (100% vs. 70.0%, p = 0.047), although other pairwise differences between software platforms were not statistically significant. Conclusions: The findings indicate that both panel dimensionality and analytical workflow influence flow cytometric MRD assessment. The extended 14-color panel improved detection performance across platforms, while software-dependent differences remained evident, highlighting the need for standardized post-acquisition analysis and independent validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers