Diagnostics (Basel, Switzerland)

InceptionTurkerNeXt: A Compact CNN and Deep Feature Engineering Framework for Image-Level Osteoid Osteoma Classification on Computed Tomography.

Sefa Key, Anil Agar, Omer Faruk Goktas, Mehmet Baygin, Sengul Dogan, Turker Tuncer

Department of Orthopedics and Traumatology, Faculty of Medicine, Firat University, Elazig 23190, Türkiye. · Department of Electronics and Automation, Technical Sciences Vocational School, Ankara Yildirim Beyazit University, Ankara 06760, Türkiye.

Key points

From the paper's conclusion
  • This exploratory study introduces InceptionTurkerNeXt, a compact convolutional neural network, and evaluates a deep feature engineering (DFE) framework built on it for image-level OO classification.

Abstract

Background/Objectives: Osteoid osteoma (OO) is a painful benign bone tumor whose nidus is best depicted on computed tomography (CT). This exploratory study introduces InceptionTurkerNeXt, a compact convolutional neural network, and evaluates a deep feature engineering (DFE) framework built on it for image-level OO classification. Methods: The backbone was pretrained on a public 26-class multi-cancer dataset of 130,000 images. The DFE framework extracts global and patch features, selects them with cumulative weighted iterative neighborhood component analysis and classifies them with a t-algorithm-based k-nearest neighbors ensemble. The single-center OO set contains 359 axial CT images (184 OO and 175 control) from 82 patients. The primary protocol was patient-grouped 10-fold cross-validation with all selection steps fitted on the training folds. Results: The backbone reached 98.94% accuracy on the 26,000-image multi-cancer test set. Under the primary protocol, the DFE framework reached 90.81% image-level accuracy (95% confidence interval 86.35-94.71%), 91.30% sensitivity and 90.29% specificity. Patient-level voting gave 93.90% accuracy (82 patients), and a separate patient-level hold-out set gave 91.55% image-level accuracy (71 images). The earlier image-level estimate (98.33%) was optimistic by 7.52 percentage points. Four fine-tuned standard backbones reached 83.29-88.02% on the same partitions. Conclusions: The framework separated OO and control CT images with approximately 91% image-level accuracy under patient-grouped validation at one center. External multi-center validation is required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

InceptionTurkerNeXt: A Compact CNN and Deep Feature Engineering Framework for Image-Level Osteoid Osteoma Classification on Computed Tomography — Science Skim