Diagnostics (Basel, Switzerland)

Automatic Detection of Dental Implant Brands and Exposure Status Using Deep Learning on Periapical Radiographs.

Chih-Hao Chang, Yi-Cheng Mao, Chien-Yu Sung, Hsin-Kai Su, Kuo-Chen Li, Yuan-Jin Lin, Shih-Lun Chen, Da-Wei Hsu,

Department of Computer Science and Information Engineering, National Central University, Taoyuan City 320317, Taiwan. · Department of Operative Dentistry, Taoyuan Chang Gung Memorial Hospital, Taoyuan City 333008, Taiwan.

Computational · n=497

Key points

From the paper's conclusion
  • Conclusions: This study demonstrates the technical feasibility and proof-of-concept of a deep learning framework for identifying dental implant brands and exposure status under robust internal validation.

Abstract

Background/Objectives: Dental implant technology has become the primary treatment modality for managing tooth loss in current clinical practice. Accurate identification of implant brands and their clinical exposure status have increasingly emerged as a critical issue in implant-related research and clinical diagnosis. Conventional approaches that rely on clinicians' experience are time-consuming and may lead to misclassification due to variations in image quality or subtle differences in implant design features across brands. Methods: This single-center study classified six categories combining two implant brands (3i and Xive) and three exposure statuses. A retrospective cohort of 497 patients (708 periapical radiographs, 928 implant instances) was partitioned using an 8:1:1 stratified ratio with strict patient-level independence. Following YOLOv8-based implant localization and ROI extraction, classification was evaluated across deep learning backbones using 5-fold cross-validation and compared against a panel of three dental specialists on a test set of 8 complex cases. Results: YOLOv8 achieved a precision of 99.39% and a sensitivity of 98.63% in the implant detection task. For the classification of implant brand and exposure status, EfficientNet-B3 achieved the best performance with an accuracy of 99.18 ± 0.85% (95% CI: [94.20%, 100.00%]) across 5-fold cross-validation, demonstrating competitive diagnostic performance alongside existing implant classification benchmarks in the literature. In a preliminary clinical feasibility assessment on representative cases, the framework demonstrated rapid algorithmic inference (mean inference time of 36.18 ms per image), providing instant decision-support potential alongside participating clinicians. Conclusions: This study demonstrates the technical feasibility and proof-of-concept of a deep learning framework for identifying dental implant brands and exposure status under robust internal validation. While offering preliminary decision-support potential, external validation on multi-center cohorts and prospective clinical trials across expanded implant systems remain necessary before clinical implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Automatic Detection of Dental Implant Brands and Exposure Status Using Deep Learning on Periapical Radiographs — Science Skim