Diagnostic Performance of Artificial Intelligence for the Detection and Segmentation of Periapical Lesions on Cone-Beam Computed Tomography: A Systematic Review and Meta-Analysis.
Mohammed Howait, Mey A Al-Habib
Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80200, Jeddah 21589, Saudi Arabia.
Key points
From the paper's conclusion- Conclusions: AI shows promising performance for CBCT-based periapical lesion detection under research conditions, whereas segmentation overlap is moderate.
Abstract
Background/Objectives: Cone-beam computed tomography (CBCT) improves periapical lesion detection, but its interpretation is expertise-dependent. This systematic review evaluated artificial intelligence (AI) for detecting, classifying, and segmenting periapical lesions on CBCT. Methods: PubMed, the Cochrane Library, Scopus, Web of Science, and Google Scholar were searched to 12 December 2025 (PROSPERO: CRD420251184440). Studies comparing AI with an expert- or annotation-based reference standard on human CBCT scans were eligible. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, and certainty of evidence with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Sensitivity and specificity were pooled with a bivariate model where complete 2 × 2 data were available, and all metrics with univariate random-effects models. Results: Eighteen studies were included (detection or classification, 16; segmentation, 6); 15 had unclear risk of bias in at least one domain, and most were retrospective and internally validated. In the bivariate model (seven studies), sensitivity was 88.2% (95% confidence interval [CI]: 77.6-94.2%) and specificity 85.1% (73.4-92.1%). Univariate pooled sensitivity was 90.9% (84.2-94.9%; 14 studies), specificity 89.7% (83.2-93.9%; 11 studies), accuracy 86.7% (78.9-92.0%; 10 studies), and F1-score 83.7% (76.4-89.1%; seven studies). The pooled lesion Dice similarity coefficient was 0.70 (0.61-0.78; six studies), indicating moderate spatial overlap with reference annotations. Heterogeneity was considerable for detection metrics (I2 = 90-96%), prediction intervals were wide (sensitivity 48-99%), and the certainty of evidence was very low. Conclusions: AI shows promising performance for CBCT-based periapical lesion detection under research conditions, whereas segmentation overlap is moderate. Equivalence to clinicians and clinical effectiveness are not established; prospective, externally validated studies with standardized reference standards are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of artificial intelligence in detecting periapical lesions: A comparative study with cone-beam computed tomography and conventional periapical radiography.Journal of clinical and experimental dentistry · 2026
- Diagnostic Performance of Artificial Intelligence in Detecting Periodontal Diseases Using Cone‐Beam Computed Tomography: A Systematic ReviewOral Diseases · 2026
- AI-Based Detection of Dental Features on CBCT: Dual-Layer Reliability AnalysisDiagnostics · 2025
- Evaluating Artificial Intelligence in Full-Arch CBCT Caries Detection: A Comparative Analysis with Clinical AssessmentJournal of Clinical Medicine · 2026
- Artificial intelligence-based segmentation of mandibular canal on cone-beam computed tomography: a systematic review and meta-analysis.Oral radiology · 2026
- Reference Standards in Artificial Intelligence Detection of Apical Periodontitis: A Narrative Review of What Reported Accuracy Measures.Diagnostics (Basel, Switzerland) · 2026