Diagnostics (Basel, Switzerland)

YOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study.

Halil Büyükdoğan, Tahir Burak Sarıtaş, Avni Tan, Abdülkadir Yalçınkaya, Erhan Abay, Muhammed Halit Yücel, Volkan Arıcı, Necati Doğan,

Department of Orthopaedics and Traumatology, Gaziosmanpaşa Hospital, Faculty of Medicine, Istinye University, Istanbul 34245, Türkiye. · Department of Orthopaedics and Traumatology, Kanuni Sultan Süleyman Training and Research Hospital, University of Health Sciences, Istanbul 34303, Türkiye.

Observational · n=258

Key points

From the paper's conclusion
  • We compared a locked YOLO11m-based model with prespecified orthopaedic physician panels using arthroscopy as the reference standard.

Abstract

Background/Objectives: Artificial intelligence (AI) may support rotator cuff MRI interpretation; however, its performance relative to clinicians at different experience levels remains uncertain. We compared a locked YOLO11m-based model with prespecified orthopaedic physician panels using arthroscopy as the reference standard. Methods: This retrospective single-centre study included a separate 300-patient model-development dataset and an arthroscopy-referenced reader cohort of 258 patients (60 intact cuffs, 86 partial-thickness tears, and 112 full-thickness tears). Twelve blinded physicians were assigned to four three-reader experience panels, and panel diagnoses were defined by a two-of-three majority. Paired accuracy comparisons used exact McNemar tests with Holm adjustment. Results: AI achieved 0.841 overall accuracy (95% CI, 0.792-0.881). The senior-specialist panel had numerically higher accuracy (0.911), but the difference from AI was not statistically significant after adjustment (Holm p = 0.060); the junior-specialist panel also did not differ from AI (0.822; Holm p = 0.649). AI showed higher paired accuracy than the senior-resident (0.729; Holm p = 0.005) and junior-resident panels (0.671; Holm p < 0.001). Partial-thickness tears had the lowest AI sensitivity (0.709). Conclusions: In this restricted-cine, three-category benchmark, AI outperformed both resident panels, whereas neither specialist panel comparison reached the adjusted significance threshold. These findings do not establish equivalence to specialists or benefit from AI-assisted reading.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

YOLO11m-Based Artificial Intelligence Versus Orthopaedic Physician Panels for Arthroscopy-Referenced Three-Category MRI Classification of the Posterosuperior Rotator Cuff: A Multi-Reader Diagnostic Accuracy Study — Science Skim